基于性能的人工耳蜗随访护理新范式
该回顾性数据库研究分析了9448例植入中的804例成人单侧人工耳蜗使用者,以CNC词识别得分评估术后性能。结果显示术后3个月平均得分为47.2%至51.5%,支持以CNC≥50%作为高表现者 cutoff;在318例有至少三次术后得分的患者中,12个月时59.7%可考虑降低随访强度。
要点
- 成人单侧人工耳蜗植入后CNC词识别得分随时间改善,12个月后趋于平台。
- CNC≥50%可作为区分高表现者与低表现者的合理 cutoff。
- 术后12个月时59.7%患者为低强度随访的合适候选者。
核心结论
- CNC≥50%是区分高表现者与低表现者的合理 cutoff。
- 术后12个月内59.7%的患者是低强度随访的良好候选者。
研究设计与样本
- 回顾性数据库研究,从9448例植入中识别804例成人单侧 recipient,其中318例有至少三次术后CNC得分。
- 采用线性混合效应回归分析CNC词性能随时间的变化。
主要发现
- 804例患者术后各时间间隔CNC得分均改善,3个月后平均性能为47.2%至51.5%。
- 318例患者中,性能从1至3个月(P = .001)、3至6个月(P = .001)、6至12个月(P = .01)显著改善,12与24个月无显著差异(P = .09)。
- 术后12个月时59.7%的患者被认为是低强度随访的候选者。
关键数值与推荐
- 高表现者 cutoff:CNC ≥ 50%。
- 低强度随访候选者:高表现者且达到性能平台,12个月时占59.7%。
临床怎么用
- 可利用CNC≥50%识别高表现者,并在术后12个月内评估是否适合降低随访强度。
- 对达到性能平台的高表现者,可考虑减少随访频率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Utilize a multi-institutional outcomes database to determine expected performance for adult cochlear implant (CI) users. Estimate the percentage of patients who are high performers and achieve performance plateau. STUDY DESIGN: Retrospective database study. METHODS: Outcomes from 9,448 implantations were mined to identify 804 adult, unilateral recipients who had one preoperative and at least one postoperative consonant-nucleus-consonant (CNC) word score. Results were examined to determine percent-correct CNC word recognition preoperatively and at 1, 3, 6, 12, and 24 months after activation. Outcomes from 318 similar patients who also had at least three postoperative CNC word scores were examined. Linear mixed-effects regression was used to examine CNC word performance over time. The time when each patient achieved maximum performance was recorded as a surrogate for time of performance plateau. Patients were assigned as candidates for less intense follow-up if they were high performers and achieved performance plateau. RESULTS: Among 804 patients with at least one postoperative score, CNC score improved at all time intervals. Average performance after the 3-month time interval was 47.2% to 51.5%, indicating a CNC ≥ 50% cutoff for high performers. Among 318 patients with at least three postoperative scores, performance improved from 1 to 3 (P = .001), 3 to 6 (P = .001), and 6 to 12 (P = .01) months. Scores from the 12- and 24-month intervals did not significantly differ (P = .09). By 12 months after activation, 59.7% of patients were considered candidates for less intense follow-up. CONCLUSION: Findings suggest that CNC ≥ 50% is a reasonable cutoff to separate high performers from low performers. Within 12 months after activation, 59.7% of patients were good candidates for less intense follow-up. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:S1-S10, 2022.
引用
- Grisel J, Miller S, Schafer EC, et al. A Novel Performance-Based Paradigm of Care for Cochlear Implant Follow-Up. Laryngoscope. 2021. PMID: 34013978. doi:10.1002/lary.29614
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。