文献速递睡眠呼吸障碍咽喉与嗓音

电极配置与脉冲强度对阻塞性睡眠呼吸暂停神经刺激中气道通畅性的影响

Effect of Electrode Configuration and Impulse Strength on Airway Patency in Neurostimulation for Obstructive Sleep Apnea.
PubMed 文献 · Laryngoscope · 2021-04-17

结果显示所有患者均可见开放效应,不同电极配置间存在变化,但无一致更优的配置。

要点

  • 电极配置改变可独立于电压增加改善气道通畅性。
  • 清醒内镜或DISE下实时刺激可评估气道开放效应。
  • HNS治疗后呼吸暂停低通气指数改善不足时可考虑内镜评估。

核心结论

  • 在治疗调整中效果不佳的患者,改变电极配置可改善气道通畅性,且独立于增加电压。

主要发现

  • 所有患者均可见开放效应,但不同电极配置间存在变化。
  • 肥胖、OSA严重程度或既往软腭手术等人口学或治疗因素与电极配置变化相关,但无一导致一致更好的气道开放。

临床怎么用

  • 对于HNS治疗启动后呼吸暂停低通气指数改善不足的病例,可考虑在清醒内镜或DISE下进行实时刺激评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: Hypoglossal nerve stimulation (HNS) has gained increasing interest for the treatment of patients with obstructive sleep apnea (OSA). Drug-induced sleep endoscopy (DISE) can both exclude improper airway collapse patterns and visualize airway changes under stimulation. Stimulation outcome effects depend on the impulse voltage and electric field resulting from the electrode configuration of the implanted device. The effects of various combinations of voltage and electric field on DISE airway patterns in contrast to awake endoscopy are unknown. STUDY DESIGN: Cohort study. METHODS: During therapy adjustment about 6 months after implantation, patients underwent a DISE and awake endoscopy with 100% and 125% of functional voltage in three typical electrode configurations (+ - +, o - o, - - -). All videos were analyzed by two separate persons for the opening of the airway at velum, tongue base, and epiglottis level. RESULTS: Thirty patients showed typical demographic data. The opening effects were visible in all patients, but there were changes between different electrode configurations. Several demographic or therapeutic aspects such as obesity, OSA severity, or prior soft palate surgery were associated with changes arising from different electrode configurations, but none resulted in a consistently better airway opening. CONCLUSIONS: In patients with poor results during the therapy adjustment, electric configuration changes can improve airway patency-an independent variable from increasing voltage. As these effects can only be seen in awake endoscopy or DISE, both endoscopies with live stimulation may be considered in cases with insufficient improvement in apnea-hypopnea index after initiation of HNS therapy. LEVEL OF EVIDENCE: Prospective case series; level 4. Laryngoscope, 131:2148-2153, 2021.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Pawlak D, Bohorquez D, König IR, et al. Effect of Electrode Configuration and Impulse Strength on Airway Patency in Neurostimulation for Obstructive Sleep Apnea. Laryngoscope. 2021. PMID: 33864394. doi:10.1002/lary.29530

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。