简明嗅觉障碍问卷在慢性鼻窦炎患者中的心理测量学特性
本研究在开发样本(n=203)和复制样本(n=281)中评估7条目简明嗅觉障碍问卷(B-QOD)的心理测量学特性。探索性因子分析显示单一因子结构,内部信度良好(Cronbach's α=0.88和0.83),信息损失极小(R=0.98和0.96),且与QOD-NS相比对SNOT-22评分无额外预测获益。结论认为B-QOD具有结构一致、可靠的单维度,信息损失小且外部预测效用优异。
要点
- B-QOD在慢性鼻窦炎患者中呈现单一因子结构,内部信度良好。
- 与原始17条目QOD-NS相比,B-QOD信息损失极小。
- B-QOD对SNOT-22的预测效用与QOD-NS相当,无额外获益。
核心结论
- 7条目B-QOD captures a structurally coherent and reliable single dimension, with minimal information loss and excellent external predictive utility when compared to the QOD-NS.
研究设计与样本
- 在开发样本(n=203)和复制样本(n=281)中评估B-QOD的心理测量学特性,包括探索性因子分析、内部信度、信息损失、验证性因子分析和增量预测效用分析。
主要发现
- 探索性因子分析显示开发样本和复制样本均呈现单一因子结构(特征值分别为4.17和3.57),载荷因子均大于0.30。
- B-QOD在开发样本和复制样本中均具有良好的内部信度(Cronbach's α分别为0.88和0.83)。
- 与QOD-NS相比,B-QOD在开发样本和复制样本中信息损失极小(R分别为0.98和0.96)。
- 验证性因子分析表明B-QOD单因子模型在开发样本和复制样本中整体拟合良好(CFI分别为0.99和0.97;SRMSR分别为0.035和0.053)。
- 增量预测效用分析显示,与B-QOD相比,QOD-NS对SNOT-22评分无额外预测获益。
临床怎么用
- 在慢性鼻窦炎患者的临床研究中,可使用7条目B-QOD替代17条目QOD-NS测量嗅觉特异性生活质量,以减少问卷负担且不损失关键信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Questionnaire of Olfactory Disorders-Negative Statements (QOD-NS) is a 17-item instrument measuring olfactory-specific quality of life (QOL). However, in clinical research patients can be overwhelmed with multiple questionnaires. We recently developed the 7-item brief QOD-NS (B-QOD). Our objective was to evaluate the psychometric properties of the B-QOD in both the development (D) sample, and in a separate replication (R) sample. METHODS: Testing on D (n = 203) and R (n = 281) samples included initial exploratory factor analysis (EFA), followed by internal reliability, information loss, and confirmatory factor analysis (CFA). Finally, incremental predictive utility analysis (IPUA) was performed by correlating the B-QOD with the 22-item Sino-Nasal Outcome Test (SNOT-22) survey. RESULTS: EFAs of both D and R demonstrated an underlying single-factor structure (eigenvalue = 4.17 and 3.57, respectively) with comparable loading factors (R > 0.30 for both). B-QOD also had good internal reliability in both D and R (Cronbach's alpha = 0.88 and 0.83, respectively). Also, there is minimal information loss with B-QOD compared to QOD-NS in both D and R (R = 0.98 and 0.96, respectively). CFA indicates that the B-QOD single-factor model has good overall fit as measured by the Comparative Fit Index (CFI) and the Standardized Root Mean Squared Residuals (SRMSR) in the D and R samples (CFI = 0.99 and 0.97; SRMSR = 0.035 and 0.053). IPUA shows that the QOD-NS offers no additional predictive benefit of SNOT-22 scores when compared with B-QOD. CONCLUSION: The 7-item B-QOD captures a structurally coherent and reliable single dimension, with minimal information loss and excellent external predictive utility when compared to the QOD-NS.
引用
- Mattos JL, Bodner TE, Mace JC, et al. Psychometric properties of the brief version of the questionnaire of olfactory disorders in patients with chronic rhinosinusitis. Int Forum Allergy Rhinol. 2021. PMID: 33864723. doi:10.1002/alr.22800
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。