噪声暴露史者听力图切迹意义的系统综述
本系统综述纳入84篇研究、共1,438,987名7至80岁个体,评估噪声暴露与3–6 kHz听力图切迹的关系。结果显示14项研究报道3 kHz切迹、63项报道4 kHz切迹、47项报道6 kHz切迹,但噪声暴露与切迹的关系并不简单,单侧切迹、3 kHz切迹及无持续高强度噪声暴露的切迹需仔细审查。
要点
- 噪声暴露与3–6 kHz听力图切迹的关系并不直接明确。
- 单侧切迹、3 kHz切迹及无持续高强度噪声暴露的切迹需仔细审查。
- 观察性研究存在高偏倚风险,结果解读需谨慎。
核心结论
- 噪声暴露与3–6 kHz听力图切迹的关系并不简单直接。
- 少数文章显示个体噪声暴露与听力图切迹存在明确关联。
- 单侧切迹、3 kHz切迹及无持续高强度噪声暴露的切迹需仔细审查。
研究设计与样本
- 系统综述纳入基于人群的研究、队列、横断面、病例对照、病例系列及病例报告。
- 共纳入84篇文章,合计1,438,987名7至80岁个体,研究来自26个国家。
- 综述注册于Prospero(CRD42017079901),遵循PRISMA指南。
主要发现
- 14项研究报道3 kHz切迹,63项报道4 kHz切迹,47项报道6 kHz切迹。
- 对82项研究采用Newcastle-Ottawa风险评估工具,强调观察性研究高偏倚风险。
关键数值与推荐
- 14项研究识别3 kHz切迹。
- 63项研究识别4 kHz切迹。
- 47项研究识别6 kHz切迹。
临床怎么用
- 解读噪声暴露者听力图切迹时需结合切迹频率、单双侧及噪声暴露史综合判断。
- 对单侧切迹、3 kHz切迹及无持续高强度噪声暴露的切迹应仔细审查。
局限性
- 纳入的观察性研究存在高偏倚风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The diagnosis of noise-induced hearing loss (NIHL) is reliant on the appraisal of audiometric data. A notch, dip or bulge, centered at the 4-kHz frequency is considered to be pathognomonic. However, guidelines applied to assist the diagnosis of NIHL often allow for a notch centered between the 3- and 6-kHz frequencies. The primary outcome of this review is to document the relationship between audiometric notching at particular frequencies and the populations in which they have been identified. DESIGN: We included all population-based studies, cohort, cross-sectional, case-control, case-series, and case reports of adults and children, with exposure to noise and with a notch, dip or bulge. The review has been registered with Prospero (Registration: CRD42017079901) and prepared in line with the PRISMA guidelines. RESULTS: We included 84 articles in the final systematic review. There were a total of 1,438,987 individuals, aged 7 to 80 years old. The studies were conducted in 26 different countries. Fourteen studies identified notching at 3 kHz, 63 studies identified notching at 4 kHz, and 47 studies identified notching at 6 kHz. The Newcastle-Ottawa risk assessment tool was performed on 82 of the studies emphasizing the high risk of bias in observational studies. CONCLUSIONS: The overwhelming outcome of this systematic review demonstrates that the relationship between noise exposure and a 3- to 6-kHz audiometric notch is not straight-forward. A handful of articles have displayed a clear association between an individual's noise exposure and an audiometric notch. Unilateral notches, notches observed at 3 kHz and notches in the absence of continued high-intensity noise exposure must be scrutinized thoroughly. The ambiguous nature of NIHL directs its continued interest.
引用
- Meghji S, Phillips J. The Significance of Audiometric Notching in Individuals With a History of Noise Exposure: A Systematic Review. Ear Hear. 2021. PMID: 33908409. doi:10.1097/AUD.0000000000001034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。