长侧壁电极阵列人工耳蜗完全植入发生率研究

Incidence of Complete Insertion in Cochlear Implant Recipients of Long Lateral Wall Arrays.
PubMed 文献 · Otolaryngol Head Neck Surg · 2021-02-16

这项回顾性研究分析了51例植入31.5毫米柔性侧壁电极阵列的成人人工耳蜗使用者,通过术后CT评估完全植入率。结果显示96.1%(49例)实现完全植入,完全植入组中位耳蜗管长33.6毫米、中位角度插入深度641°。结论认为完全植入在多数病例中可行,且不受本队列耳蜗管长范围限制。

要点

  • 31.5毫米柔性侧壁阵列完全植入率达96.1%。
  • 完全植入组中位耳蜗管长33.6毫米,中位角度插入深度641°。
  • 部分植入病例耳蜗管长较短且角度插入深度较浅,但不足以证明耳蜗管长单独限制完全植入。

核心结论

  • 31.5毫米柔性阵列完全植入在多数病例中可行,且不受本队列耳蜗管长范围限制。

研究设计与样本

  • 回顾性研究,纳入51例植入31.5毫米柔性侧壁阵列的成人人工耳蜗使用者,术后CT评估完全植入(所有触点位于耳蜗内)。

主要发现

  • 完全植入率为96.1%(49/51)。
  • 完全植入组中位耳蜗管长33.6毫米(范围30.3-37.9毫米),中位角度插入深度641°(范围533-751°)。
  • 2例部分植入者耳蜗管长分别为31.8毫米和32.3毫米,角度插入深度分别为542°和575°。

关键数值与推荐

  • 完全植入定义为所有电极触点位于耳蜗内。
  • 部分植入病例的较浅角度插入深度不支持耳蜗管长单独阻止完全植入的观点。

临床怎么用

  • 对于植入31.5毫米柔性侧壁阵列的成人患者,完全植入可期,但需注意耳蜗形态变异可能影响植入阻力。

局限性

  • 回顾性设计,样本量有限(51例),仅评估耳蜗管长,未充分分析其他耳蜗形态变异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: High rates of partial insertion have been reported for cochlear implant (CI) recipients of long lateral wall electrode arrays, presumably caused by resistance encountered during insertion due to cochlear morphology. With recent advances in long-electrode array design, we sought to investigate (1) the incidence of complete insertions among patients implanted with 31.5-mm flexible arrays and (2) whether complete insertion is limited by cochlear duct length (CDL). STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. METHODS: Fifty-one adult CI recipients implanted with 31.5-mm flexible lateral wall arrays underwent postoperative computed tomography to determine the rate of complete insertion, defined as all contacts being intracochlear. CDL and angular insertion depth (AID) were compared between complete and partial insertion cohorts. RESULTS: Most cases had a complete insertion (96.1%, n = 49). Among the complete insertion cohort, the median CDL was 33.6 mm (range, 30.3-37.9 mm), and median AID was 641° (range, 533-751°). Two cases of partial insertion had relatively short CDL (31.8 mm and 32.3 mm) and shallow AID (542° and 575°). Relatively shallow AID for the 2 cases of partial insertion fails to support the idea that CDL alone prevents a complete insertion. CONCLUSION: Complete insertion of a 31.5-mm flexible array is feasible in most cases and does not appear to be limited by the range of CDL observed in this cohort. Future studies are needed to estimate other variations in cochlear morphology that could predict resistance and failure to achieve complete insertion with long arrays.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Canfarotta MW, Dillon MT, Brown KD, et al. Incidence of Complete Insertion in Cochlear Implant Recipients of Long Lateral Wall Arrays. Otolaryngol Head Neck Surg. 2021. PMID: 33588627. doi:10.1177/0194599820987456

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。