主动中耳植入者的基频掩蔽释放:与正常听力者的比较
研究纳入13例Vibrant Soundbridge主动中耳植入(AMEI)使用者和13名正常听力者,采用改进的奥尔登堡句子测试模拟竞争说话者场景,将掩蔽句基频上移4、8、12个半音,自适应测量言语接收阈。结果显示两组在基频差≥8个半音时言语感知显著改善,AMEI组掩蔽释放约3 dB,正常听力组约5–5.6 dB;植入侧耳道额外堵塞不影响言语表现。
要点
- 基频差≥8个半音时AMEI使用者可获得约3 dB的掩蔽释放。
- 正常听力者的基频掩蔽释放约5–5.6 dB,优于AMEI使用者。
- 植入侧耳道额外堵塞不影响AMEI使用者的言语表现。
核心结论
- 尽管AMEI使用者存在耳蜗损伤相关问题,当目标句与掩蔽句基频差至少8个半音时,植入放大仍能带来基于基频差的掩蔽释放。
- 植入侧耳道额外堵塞不影响言语表现。
研究设计与样本
- 研究纳入13例Vibrant Soundbridge主动中耳植入(AMEI)使用者和13名正常听力(NH)者。
- 采用改进的奥尔登堡句子测试模拟竞争说话者场景,掩蔽句基频上移4、8、12个半音,自适应变化掩蔽声级评估言语接收阈。
- AMEI使用者在植入对侧耳道堵塞(AMEIcontra)和双耳耳道堵塞(AMEIboth)两种配置下测试。
主要发现
- 两组言语感知均随目标与掩蔽句基频差增大而改善,基频差至少8个半音时差异显著。
- 基频差8个半音时,掩蔽释放AMEIcontra为3.0 dB(p = 0.009),AMEIboth为2.9 dB(p = 0.015),NH为5.6 dB(p < 0.001)。
- 基频差12个半音时,掩蔽释放AMEIcontra为3.5 dB(p = 0.002),AMEIboth为3.4 dB(p = 0.003),NH为5.0 dB(p < 0.001)。
临床怎么用
- 对于Vibrant Soundbridge AMEI使用者,可利用目标与掩蔽说话者间至少8个半音的基频差来改善噪声下言语感知。
- 植入侧耳道堵塞与否不影响言语表现,临床测试时无需特别考虑该因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Temporal fine structure information such as low-frequency sounds including the fundamental frequency (F0) is important to separate different talkers in noisy environments. Speech perception in noise is negatively affected by reduced temporal fine structure resolution in cochlear hearing loss. It has been shown that normal-hearing (NH) people as well as cochlear implant patients with preserved acoustic low-frequency hearing benefit from different F0 between concurrent talkers. Though patients with an active middle ear implant (AMEI) report better sound quality compared with hearing aids, they often struggle when listening in noise. The primary objective was to evaluate whether or not patients with a Vibrant Soundbridge AMEI were able to benefit from F0 differences in a concurrent talker situation and if the effect was comparable to NH individuals. DESIGN: A total of 13 AMEI listeners and 13 NH individuals were included. A modified variant of the Oldenburg sentence test was used to emulate a concurrent talker scenario. One sentence from the test corpus served as the masker and the remaining sentences as target speech. The F0 of the masker sentence was shifted upward by 4, 8, and 12 semitones. The target and masker sentences were presented simultaneously to the study subjects and the speech reception threshold was assessed by adaptively varying the masker level. To evaluate any impact of the occlusion effect on speech perception, AMEI listeners were tested in two configurations: with a plugged ear-canal contralateral to the implant side, indicated as AMEIcontra, or with both ears plugged, indicated as AMEIboth. RESULTS: In both study groups, speech perception improved when the F0 difference between target and masker increased. This was significant when the difference was at least 8 semitones; the F0-based release from masking was 3.0 dB in AMEIcontra (p = 0.009) and 2.9 dB in AMEIboth (p = 0.015), compared with 5.6 dB in NH listeners (p < 0.001). A difference of 12 semitones revealed a F0-based release from masking of 3.5 dB in the AMEIcontra (p = 0.002) and 3.4 dB in the AMEIboth (p = 0.003) condition, compared with 5.0 dB in NH individuals (p < 0.001). CONCLUSIONS: Though AMEI users deal with problems resulting from cochlear damage, hearing amplification with the implant enables a masking release based on F0 differences when F0 between a target and masker sentence was at least 8 semitones. Additional occlusion of the ear canal on the implant side did not affect speech performance. The current results complement the knowledge about the benefit of F0 within the acoustic low-frequency hearing.
引用
- Auinger AB, Liepins R, Kaider A, et al. Speech Segregation in Active Middle Ear Stimulation: Masking Release With Changing Fundamental Frequency. Ear Hear. 2021. PMID: 33369941. doi:10.1097/AUD.0000000000000973
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。