文献速递耳科与耳神经

神经纤维瘤病2型患者双侧听觉脑干植入

Bilateral Auditory Brainstem Implants in Patients With Neurofibromatosis 2.
PubMed 文献 · Otolaryngol Head Neck Surg · 2020-12-15

回顾性分析1989至2019年24例神经纤维瘤病2型(NF2)患者序贯放置听觉脑干植入(ABI)的指征与听力结局。第二侧植入指征包括第一侧严重非听觉症状、听力结果边缘、技术过时或第一侧恶化;

要点

  • 第一侧ABI效果不佳者应考虑第二侧植入。
  • 多数患者第二侧ABI后主观改善,但需更多客观评估。
  • 第二侧植入指征包括非听觉副作用和听力结果边缘。

核心结论

  • 第一侧ABI表现不佳的患者应考虑第二侧ABI。
  • 多数患者第二侧ABI后主观改善,但需更多研究进行客观评估。

研究设计与样本

  • 回顾性综述,纳入1989至2019年序贯放置ABI的24例NF2患者,来自三级转诊中心。

主要发现

  • 第二侧植入指征:第一侧严重非听觉症状11例、听力结果边缘9例、技术过时2例、第一侧恶化2例。
  • 7例为双侧使用者,1例因无显著改善一年后停止双侧使用,1例失访。

关键数值与推荐

  • 第二侧ABI指征包括第一侧严重非听觉症状、听力结果边缘、技术过时或第一侧恶化。

临床怎么用

  • 对第一侧ABI效果不佳的NF2患者,可考虑第二侧ABI以改善主观结局。

局限性

  • 需更多研究进行更好的客观评估以确认改善。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To discuss indications for bilateral auditory brainstem implants (ABIs), compare audiometric outcomes of unilateral vs bilateral ABIs, and determine if patients have improved outcomes with addition of a second-side implant. STUDY DESIGN: Retrospective review of 24 patients with neurofibromatosis 2 (NF2) who underwent sequential placement of ABIs from 1989 to 2019. SETTING: Tertiary referral center. METHODS: Charts were reviewed for indication for second-side surgery, use of implants, and audiometric outcomes. Implants placed in the past 30 years were included in the study. Northwestern University Children's Perception of Speech (NU-CHIPS) and/or City University of New York (CUNY) sentence scores were compared in unilateral and bilateral conditions. RESULTS: Indications for a second-side implant included first-side implants with severe nonauditory symptoms (11), marginal audiometric results (9), outdated technology (2), or deterioration of first side (2). Seven patients are bilateral users and 1 patient discontinued bilateral use after a year due to no significant improvement over unilateral use. One patient with initial bilateral use was lost to follow-up. Thirteen patients are unilateral users due to nonaudiometric side effects or poor audiometric outcomes with the first side. Two patients are complete nonusers. Seventy-five percent had improved audiometric outcomes after the second-side implant, and 20% had stable findings. CONCLUSIONS: Second-side ABIs should be consider in patients with poor performance from a first-side implant. Most patients demonstrate subjective improvement with the second ABI. More research is needed for better objective assessments of improvements.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Noonan KY, Rock J, Barnard Z, et al. Bilateral Auditory Brainstem Implants in Patients With Neurofibromatosis 2. Otolaryngol Head Neck Surg. 2020. PMID: 33317418. doi:10.1177/0194599820977420

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。