文献速递耳科与耳神经小儿耳鼻咽喉

头动对单侧聋人工耳蜗患者声源定位的影响

Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.
PubMed 文献 · Ear Hear · 2020-01-01

研究纳入8例单侧聋人工耳蜗(SSD-CI)患者,在耳蜗开/关状态下测试头动对前后和左右声源定位的影响,并设单耳堵塞与双耳正常听力对照。结果显示头静止时SSD-CI患者前后定位近随机水平,头动可显著改善前后与左右定位,且开耳蜗有额外增益。

要点

  • 头静止时SSD-CI患者对高频声源前后定位近随机水平。
  • 头动可改善SSD-CI患者前后与左右定位,关耳蜗时改善已显著。
  • 开耳蜗进一步改善左右定位并助前后定位接近完美。

核心结论

  • SSD-CI患者头静止时前后定位能力较差,但头动可显著改善其前后与左右定位表现。
  • 头动带来的改善主要在耳蜗关闭时出现,提示非植入耳起主要作用,开耳蜗有额外增益。

研究设计与样本

  • 研究纳入8例SSD-CI患者,在耳蜗开与关两种条件下测试。
  • 对照包括8例单耳堵塞的正常听力(NH)者和8例双耳未堵塞的NH者。
  • 声源为2–8 kHz带通滤波的3秒高斯噪声,由围绕受试者、间隔60°的6个扬声器呈现。

主要发现

  • 头静止时,单耳堵塞NH者与SSD-CI患者(耳蜗开或关)对高频声源前后定位接近随机水平。
  • 允许头动改善了所有受试者在前后和左右维度上的定位表现。
  • SSD-CI患者耳蜗关闭时头动大幅减少前后反转,耳蜗开启联合头动使前后定位接近完美。
  • 开启耳蜗也改善了SSD-CI患者的左右定位表现。
  • 双耳未堵塞NH者在有无头动时均能正确定位前后与左右半野。

关键数值与推荐

  • 声源定位测试使用2–8 kHz带通滤波的3秒高斯噪声,扬声器间隔60°。
  • 头动条件为受试者在试次间旋转头部(原文公式未提供具体角度)。

临床怎么用

  • 对SSD-CI患者进行声源定位评估时应考虑头动条件,头静止结果可能低估其能力。
  • 可鼓励SSD-CI患者利用头动改善前后定位,尤其在耳蜗关闭时仍有明显获益。

局限性

  • 样本量较小(SSD-CI患者8例,每组NH者8例)。
  • 头动角度等具体参数在摘要中以公式表示,未提供数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performance. The resulting behavioral data were used for further analyses investigating the value of so-called "monaural" spectral shape cues for front-back sound source localization. DESIGN: Eight SSD-CI patients were tested with their cochlear implant (CI) on and off. Eight normal-hearing (NH) listeners, with one ear plugged during the experiment, and another group of eight NH listeners, with neither ear plugged, were also tested. Gaussian noises of 3-sec duration were band-pass filtered to 2-8 kHz and presented from 1 of 6 loudspeakers surrounding the listener, spaced 60° apart. Perceived sound source localization was tested under conditions where the patients faced forward with the head stationary, and under conditions where they rotated their heads between (Equation is included in full-text article.). RESULTS: (1) Under stationary listener conditions, unilaterally-plugged NH listeners and SSD-CI listeners (with their CIs both on and off) were nearly at chance in determining the front-back location of high-frequency sound sources. (2) Allowing rotational head movements improved performance in both the front-back and left-right dimensions for all listeners. (3) For SSD-CI patients with their CI turned off, head rotations substantially reduced front-back reversals, and the combination of turning on the CI with head rotations led to near-perfect resolution of front-back sound source location. (4) Turning on the CI also improved left-right localization performance. (5) As expected, NH listeners with both ears unplugged localized to the correct front-back and left-right hemifields both with and without head movements. CONCLUSIONS: Although SSD-CI listeners demonstrate a relatively poor ability to distinguish the front-back location of sound sources when their head is stationary, their performance is substantially improved with head movements. Most of this improvement occurs when the CI is off, suggesting that the NH ear does most of the "work" in this regard, though some additional gain is introduced with turning the CI on. During head turns, these listeners appear to primarily rely on comparing changes in head position to changes in monaural level cues produced by the direction-dependent attenuation of high-frequency sounds that result from acoustic head shadowing. In this way, SSD-CI listeners overcome limitations to the reliability of monaural spectral and level cues under stationary conditions. SSD-CI listeners may have learned, through chronic monaural experience before CI implantation, or with the relatively impoverished spatial cues provided by their CI-implanted ear, to exploit the monaural level cue. Unilaterally-plugged NH listeners were also able to use this cue during the experiment to realize approximately the same magnitude of benefit from head turns just minutes after plugging, though their performance was less accurate than that of the SSD-CI listeners, both with and without their CI turned on.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Pastore MT, Natale SJ, Clayton C, et al. Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off. Ear Hear. 2020. PMID: 33136640. doi:10.1097/AUD.0000000000000882

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。