双耳音高融合:宽融合人工耳蜗使用者的双耳音高平均效应
本研究测量了12名成人人工耳蜗使用者(6名双模式、6名双侧)的融合音高,发现融合音高是双耳音高的加权平均,权重随参考刺激对的音高差异变化,较近时等权平均、较远时低音主导。该效应与助听器使用者相似,但个体间变异更大。
要点
- 人工耳蜗使用者的融合音高呈加权平均,近音高等权、远音高低音主导。
- 双模式使用者平均区域约0.5–2.3倍频程,双侧使用者约0.4–1.5倍频程。
- 部分案例中平均区域偏向刺激变异更大的耳,个体间变异较大。
核心结论
- 人工耳蜗使用者的融合音高加权效应与助听器使用者相似,提示双耳音高平均可能是听障者共有的机制。
研究设计与样本
- 研究纳入12名成人人工耳蜗使用者,包括6名双模式使用者(一侧人工耳蜗对侧助听器)和6名双侧人工耳蜗使用者。
- 通过双耳同时分听呈现参考与比较刺激,测量融合范围及融合音高匹配。
主要发现
- 融合音高加权随参考刺激对的音高差异变化:音高较近时等权平均,较远时低音主导。
- 平均区域在双模式使用者中通常为参考刺激周围0.5至2.3倍频程,在双侧使用者中为0.4至1.5倍频程。
- 部分案例中平均区域偏向刺激变异更大的耳。
- 人工耳蜗使用者在音高平均范围和偏倚效应上均表现出比助听器使用者更大的个体间变异。
临床怎么用
- 临床评估人工耳蜗使用者双耳音高融合时,需考虑融合音高为加权平均且个体差异大。
局限性
- 样本量较小(12名成人),可能限制结果的普遍性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Individuals who use hearing aids (HAs) or cochlear implants (CIs) can experience broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 to 4 octaves are perceptually integrated across ears. Previously, it was shown in HA users that the fused pitch is a weighted average of the two monaural pitches, ranging from equal weighting to dominance by the lower pitch. The goal of this study was to systematically measure the fused pitches in adult CI users, and determine whether CI users experience similar pitch averaging effects as observed in HA users. DESIGN: Twelve adult CI users (Cochlear Ltd, Sydney, Australia) participated in this study: six bimodal CI users, who wear a CI with a contralateral HA, and six bilateral CI users. Stimuli to HA ears were acoustic pure tones, and stimuli to CI ears were biphasic pulse trains delivered to individual electrodes. Fusion ranges, the ranges of frequencies/electrodes in the comparison ear that were fused with a single electrode (electrode 22, 18, 12, or 6) in the reference ear, were measured using simultaneous, dichotic presentation of reference and comparison stimuli in opposite ears, and varying the comparison stimulus. Once the fusion ranges were measured, the fused binaural pitch of a reference-pair stimulus combination was measured by finding a pitch match to monaural comparison stimuli presented to the paired stimulus ear. RESULTS: Fusion pitch weighting in CI users varied depending on the pitch difference of the reference-pair stimulus combination, with equal pitch averaging occurring for stimuli closer in pitch and lower pitch dominance occurring for stimuli farther apart in pitch. The averaging region was typically 0.5 to 2.3 octaves around the reference for bimodal CI users and 0.4 to 1.5 octaves for bilateral CI users. In some cases, a bias in the averaging region was observed toward the ear with greater stimulus variability. CONCLUSIONS: Fusion pitch weighting effects in CI users were similar to those observed previously in HA users. However, CI users showed greater inter-subject variability in both pitch averaging ranges and bias effects. These findings suggest that binaural pitch averaging could be a common underlying mechanism in hearing-impaired listeners.
引用
- Oh Y, Reiss LAJ. Binaural Pitch Fusion: Binaural Pitch Averaging in Cochlear Implant Users With Broad Binaural Fusion. Ear Hear. 2020. PMID: 33136622. doi:10.1097/AUD.0000000000000866
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。