文献速递耳科与耳神经

深化对耳蜗电图的理解:实时记录分析

Toward a Better Understanding of Electrocochleography: Analysis of Real-Time Recordings.
PubMed 文献 · Ear Hear · 2020-01-01

结果显示,幅度下降超过61%且斜率为0.2 µV/秒的事件与更差的残余听力保留相关。

要点

  • 幅度下降61%且斜率0.2 µV/秒是预测相对听力损失25%的最佳截断标准。
  • 约四分之三患者术中至少出现一次此类事件,多发生于完全插入前不久。
  • 事件数量增加与各频率残余听力阈值恶化相关,信号恢复与听力结局无关。

核心结论

  • 幅度下降超过持续信号的61%且斜率为0.2 µV/秒的事件与更差的 acoustic 听力保留相关。

主要发现

  • 相对听力损失25%的最佳截断标准为幅度下降61%且斜率0.2 µV/秒。
  • 约四分之三患者术中至少出现一次此类事件,多数发生于完全插入前不久。
  • 事件数量增加时各频率中位残余听力阈值恶化,幅度下降越大趋势越差。
  • 事件后信号恢复与 acoustic 听力结局无相关性。

关键数值与推荐

  • 幅度下降61%且斜率0.2 µV/秒预测相对听力损失25%的截断标准。

临床怎么用

  • 术中实时耳蜗电图事件(幅度下降>61%且斜率0.2 µV/秒)可提示术后听力保留更差。
  • 明确定义的耳蜗电图事件有潜力指导人工耳蜗植入手术决策。

局限性

  • 信号恢复与听力结局无法关联,且需进一步验证自动化分析可行性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Real-time electrocochleography (ECochG) has been used as a monitoring tool during cochlear implantation (CI), whereby, amplitude drops have been correlated with postoperative acoustic hearing results. However, no consensus has been reached as to how a single event of an amplitude drop should be characterized. The aim of this study was to identify ECochG events that predict loss of hearing 1 month after surgery. DESIGN: Fifty-five patients were included in this prospective cohort study. Real-time ECochG measurements were performed during CI electrode insertion. Single ECochG events were characterized according to their amplitude loss and slope steepness. RESULTS: Using receiver operating characteristic analyses, the most efficient cut-off criterion for a relative hearing loss of 25% was an amplitude loss of 61% at a fixed slope steepness of 0.2 µV/sec. Three-quarters of our population had at least one such event during implantation. Most events occurred shortly before full insertion. With increasing number of events, median residual hearing thresholds deteriorated for all frequencies. Larger amplitude drops trended toward worse hearing preservation. Signal recovery after an ECochG event could not be correlated to acoustic hearing outcomes. CONCLUSIONS: Our data suggest that amplitude drops exceeding 61% of the ongoing signal at a slope steepness of 0.2 µV/sec are correlated with worse acoustic hearing preservation. Clearly defined ECochG events have the potential to guide surgeons during CI in the future. This is essential if a fully automated data analysis is to be employed or benchmarking undertaken.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Weder S, Bester C, Collins A, et al. Toward a Better Understanding of Electrocochleography: Analysis of Real-Time Recordings. Ear Hear. 2020. PMID: 33136631. doi:10.1097/AUD.0000000000000871

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。