文献速递鼻科

三种鼻内雾化装置在三维打印模型与志愿者中的评估:一项初步研究

Assessment of three types of intranasal nebulization devices in three-dimensional printed models and volunteers: a pilot study.
PubMed 文献 · Int Forum Allergy Rhinol · 2020-07-20

本研究在儿童鼻腔、成人鼻中隔偏曲鼻腔及术后鼻窦的三维打印模型中比较面罩、双头喷嘴和单头喷嘴雾化亚甲蓝溶液的沉积染色评分,并在31名志愿者中评估生理盐水雾化的不良效应。结果显示单头喷嘴在中鼻甲、中鼻道及前筛窦的沉积显著优于面罩和双头喷嘴,而各装置不良效应均为轻度且发生率与VAS评分无显著差异。

要点

  • 单头喷嘴向鼻腔外侧壁和鼻窦的气溶胶递送效果最优。
  • 面罩的鼻窦沉积有限,不推荐作为鼻内雾化首选。
  • 各装置不良效应均为轻度且组间无显著差异。

核心结论

  • 单头喷嘴是向鼻腔外侧壁和鼻窦递送气溶胶最有效的装置,面罩的鼻窦沉积有限。
  • 鼻内雾化耐受性良好,各装置间不良效应相当。

研究设计与样本

  • 在儿童鼻腔、成人鼻中隔偏曲鼻腔及术后鼻窦的三维打印模型中比较面罩、双头喷嘴和单头喷嘴雾化亚甲蓝溶液的染色评分。
  • 31名志愿者接受不同装置生理盐水雾化,采用视觉模拟量表(VAS)评估不良效应。

主要发现

  • 儿童及成人鼻腔模型的中鼻甲和中鼻道染色评分以及鼻窦模型的前筛窦评分,单头喷嘴均显著高于面罩和双头喷嘴(均p < 0.05;效应量η2均高于0.68)。
  • 31名志愿者中鼻部刺激、面部压迫/疼痛、耳闷/耳痛、后鼻滴漏和咽喉刺激/咳嗽等不良效应均为轻度,各装置间发生率和VAS评分差异无统计学意义(均p > 0.05)。

临床怎么用

  • 临床选择鼻内雾化装置时可优先考虑单头喷嘴以优化鼻腔外侧壁和鼻窦沉积。
  • 面罩因鼻窦沉积有限,不宜作为鼻内雾化递送的首选装置。

局限性

  • 本研究为初步研究,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intranasal nebulization is an effective treatment for chronic rhinosinusitis and allergic rhinitis; however, terminal inhalation devices have not been fully studied. We compared the sinonasal aerosol distributions and adverse effects of different inhalation units. METHODS: A mask, double-head nozzle, and single-head nozzle were applied to atomize the methylene blue solution to 3-dimensional printed models of the pediatric nasal cavity, adult nasal cavity with septal deviation, and postsurgical paranasal sinuses, and staining of the different sites was scored. Volunteers received nebulization of normal saline via different devices; thereafter, the adverse effects were assessed using the visual analogue scale (VAS). RESULTS: After nebulization, the staining scores for the middle turbinate and middle meatus of the pediatric and adult nasal cavity models and the score for the anterior ethmoid sinus of the sinus model with the single-head nozzle were significantly higher than those with the mask and double-head nozzle (all p < 0.05; η2 for effect size estimates were above 0.68). Among the 31 volunteers, the adverse effects, including nasal irritation, facial pressure/pain, ear fullness/pain, postnasal drip, and throat irritation/cough, were mild. The variations in the incidence and VAS scores of the adverse effects among the devices were not significant (all p > 0.05). CONCLUSION: The single-head nozzle was the most effective device in aerosol delivery to the lateral wall of the nasal cavity and sinuses; conversely, the mask yielded limited sinonasal deposition. Intranasal nebulization was well tolerated, and the adverse effects among the devices were comparable. These findings are meaningful for selecting and developing inhalation units.

来源:Int Forum Allergy Rhinol,查看原文。版权归原作者所有。

引用

  1. Dong D, Cai F, Huang S, et al. Assessment of three types of intranasal nebulization devices in three-dimensional printed models and volunteers: a pilot study. Int Forum Allergy Rhinol. 2020. PMID: 32687694. doi:10.1002/alr.22657