头晕症状量表的重测信度研究
本研究评估头晕症状量表(DSP)在150例成年头晕患者中的重测信度,平均间隔1.58天。结果显示各条目Pearson相关系数0.67-0.91,7个亚组内ICC为0.85-0.94,最小可检测变化为16%-25%。DSP重测信度中至强,可用于头晕鉴别诊断。
要点
- DSP重测信度中至强(ICC 0.85-0.94),各亚组内部一致性良好(Cronbach's α >0.7,PPPD接近0.7)。
- 各亚组最小可检测变化(MDC)为16%(PPPD)至25%(不稳感),提示临床变化需超过此范围。
- DSP联合头晕残障量表(DHI)可评估头晕损伤与残疾/障碍,并减少症状报告偏倚。
核心结论
- DSP的重测信度为中至强,各亚组ICC为0.85-0.94。
- 确定了7个亚组的最小可检测变化(MDC)值,范围为16%至25%。
- DSP联合头晕残障量表(DHI)可评估头晕损伤和残疾/障碍。
研究设计与样本
- 研究纳入150例转诊至范德堡大学医学中心平衡障碍门诊的成年患者,平均年龄56.79岁(SD 15.69岁)。
- 患者完成两次DSP评估,平均间隔1.58天(SD 1.78天)。
- DSP采用0-100 mm视觉模拟量表(0 mm=强烈不同意,100 mm=强烈同意),并外推至原始5点Likert量表(0分=强烈不同意,4分=强烈同意)。
主要发现
- 各条目Pearson相关系数为0.67至0.91(均值0.80,p < 0.001)。
- 7个亚组的Cronbach's α系数均>0.7,仅PPPD亚组接近0.7。
- 7个亚组的组内相关系数(ICC)为0.85至0.94,显示中至强重测信度。
- MDC值范围为16%(PPPD)至25%(不稳感)。
关键数值与推荐
- DSP每个亚组得分范围为0至100%。
- 重测信度评估采用Pearson相关系数和组内相关系数(ICC)。
- 内部一致性信度评估采用Cronbach's α系数。
- MDC用于评估绝对变异/测量误差。
临床怎么用
- DSP可用于初级保健提供者、普通耳鼻咽喉科医生等对头晕、眩晕或不稳患者进行鉴别诊断。
- DSP联合DHI可全面评估头晕损伤和残疾/障碍。
- 临床解读DSP亚组评分变化时,需超过对应亚组的MDC值(16%-25%)才考虑真实变化。
- DSP可能有助于观察头晕疾病的自然史。
- DSP提供对患者报告症状的偏倚较少的评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This investigation was conducted to measure the test-retest reliability of the Dizziness Symptom Profile (DSP). The DSP was developed to assist primary care providers, general otolaryngologists, and other health care providers in the development of a differential diagnosis for patients who present with dizziness, vertigo, or unsteadiness. The DSP yields a score ranging from 0 to 100% for each of 7 subscales. Each subscale represents a different diagnosis including benign paroxysmal positional vertigo, Ménière's disease, persistent postural-perceptual dizziness (PPPD), superior semi-circular canal dehiscence, vestibular migraine, vestibular neuritis, and general unsteadiness. DESIGN: Subjects were 150 adult patients (mean age 56.79 years, SD 15.69 years) referred to the Balance Disorders Clinic at Vanderbilt University Medical Center. Subjects completed two administrations of the DSP. The mean interval between test administrations was 1.58 days (SD 1.78 days). The response modes for the DSP were both a 0 to 100 mm visual analog scale (scored 0 mm = "strongly disagree" to 100 mm = "strongly agree") and, by extrapolation, the original 5-point Likert scale where the anchors were "strongly disagree" (scored 0 points) and "strongly agree" (scored 4 points). RESULTS: Pearson correlation coefficients were calculated to assess test-retest reliability for individual DSP items, and ranged from r = 0.67 to 0.91 (mean 0.80; p < 0.001). Cronbach's α coefficients were calculated to assess internal consistency reliability of items comprising the seven subscales. Each subscale had an acceptable level of internal consistency (Cronbach's α coefficients > 0.7) with the exception of PPPD which approached 0.7. Intraclass correlation coefficient estimates and their 95% confidence intervals were also calculated to assess the relative reliability of the subscales. All 7 subscales showed moderate to strong test-retest reliability, with intraclass correlation coefficients ranging from 0.85 to 0.94. Minimal detectable change (MDC) scores were calculated to assess absolute variability/measurement error for the seven subscale scores (which range from 0 to 100%). MDC values ranged from 16% (PPPD) to 25% (unsteadiness). CONCLUSIONS: (1) The test-retest reliability of the DSP is moderate to strong. (2) MDC values for each subscale were determined. (3) The DSP coupled with the Dizziness Handicap Inventory enables the clinician to evaluate the constructs of dizziness impairment, and disability/handicap. (4) The DSP may help provide a window to the natural history of dizziness disease(s). (5) The DSP provides a less biased assessment of the symptoms reported by the patient.
引用
- Landon-Lane RL, Piker EG, Jacobson GP, et al. Test-Retest Reliability of the Dizziness Symptom Profile. Ear Hear. 2021. PMID: 32701727. doi:10.1097/AUD.0000000000000918
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。