本研究通过尸头模拟实验,评估内镜鼻内手术中飞沫和飞溅物的产生模式。结果显示常规鼻科手术飞沫产生极少,动力设备在鼻腔外激活则造成严重污染,同时吸引可消除钻孔产生的飞沫。

要点

  • 常规鼻内镜、鼻中隔成形术及冷钢FESS未见飞沫飞溅
  • 微debrider FESS及钻孔产生少量<1mm飞沫,同时吸引可消除
  • 动力设备在鼻腔外激活导致严重飞沫污染,应避免

核心结论

  • 常规鼻科手术飞沫产生极少,钻孔飞沫可通过同时吸引减轻,应避免在鼻腔外激活动力设备。

研究设计与样本

  • 尸头模拟系列研究,在专用手术实验室对2例尸头标本滴入荧光素溶液后进行内镜鼻内手术操作。

主要发现

  • 鼻内镜、鼻中隔成形术联合微debrider辅助下鼻甲成形术、冷钢FESS及所有使用超声吸引器的实验条件下,测量手术野内未见荧光素飞沫或飞溅。
  • 微debrider FESS见2个<1mm飞沫,距离10cm内;金刚石钻头钻蝶骨嘴见8个<1mm飞沫,距离12cm;切割钻头钻额嘴见5个<1mm飞沫,距离9cm;钻孔时同时吸引则无飞沫或飞溅。
  • 对照条件即钻头在鼻腔外激活导致严重污染,11个2cm飞沫,距离13cm。

临床怎么用

  • 常规鼻科手术中飞沫传播风险低,但应避免在鼻腔外激活动力设备,钻孔时使用同时吸引可减少飞沫产生。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The primary mode of viral transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is thought to occur through the spread of respiratory droplets. The objective of this study was to investigate droplet and splatter patterns resulting from common endoscopic endonasal procedures. STUDY DESIGN: Cadaver simulation series. SETTING: Dedicated surgical laboratory. SUBJECTS AND METHODS: After instilling cadaver head specimens (n = 2) with fluorescein solution, endoscopic endonasal procedures were systematically performed to evaluate the quantity, size, and distance of droplets and splatter following each experimental condition. RESULTS: There were no observable fluorescein droplets or splatter noted in the measured surgical field in any direction after nasal endoscopy, septoplasty with microdebrider-assisted turbinoplasty, cold-steel functional endoscopic sinus surgery (FESS), and all experimental conditions using an ultrasonic aspirator. Limited droplet spread was noted with microdebrider FESS (2 droplets, <1 mm in size, within 10 cm), drilling of the sphenoid rostrum with a diamond burr (8, <1 mm, 12 cm), and drilling of the frontal beak with a cutting burr (5, <1 mm, 9 cm); however, the use of concurrent suction while drilling resulted in no droplets or splatter. The control condition of external activation of the drill resulted in gross contamination (11, 2 cm, 13 cm). CONCLUSION: Our results indicate that there is very little droplet generation from routine rhinologic procedures. The droplet generation from drilling was mitigated with the use of concurrent suction. Extreme caution should be used to avoid activating powered instrumentation outside of the nasal cavity, which was found to cause droplet contamination.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。