文献速递耳科与耳神经小儿耳鼻咽喉

儿童人工耳蜗植入者纯音阈值与耳蜗微音电位阈值的比较

Comparison of Pure-Tone Thresholds and Cochlear Microphonics Thresholds in Pediatric Cochlear Implant Patients.
PubMed 文献 · Ear Hear · 2020-01-01

结果显示在125至2000 Hz范围内两者显著相关(r=0.77,p<0.01),平均差异0.4 dB(±14 dB),低频相关性更高,提示CM/DIF阈值可客观监测残留听力。

要点

  • 儿童人工耳蜗植入者中,CM/DIF阈值与行为测听阈值在125–2000 Hz显著相关(r=0.77)。
  • 低频(125、250、500 Hz)相关性较高(r=0.82、0.74、0.69),高频(1000、2000 Hz)相关性较低(r=0.41、0.32)。
  • CM/DIF阈值与行为阈值平均差异0.4 dB(±14 dB),可用于难以测试儿童的客观听力监测。

核心结论

  • 耳内耳蜗电图可测量儿童人工耳蜗植入者植入耳的CM/DIF阈值,与行为测听阈值相似,尤以低频为著。

研究设计与样本

  • 行为测听采用常规、条件游戏或视觉强化测听,测试频率为125、250、500、1000、2000 Hz的啭音。
  • 耳蜗电图采用50毫秒声学短纯音诱发,记录电极为最蜗顶的耳内电极,参考电极为耳外电极。

主要发现

  • 行为测听与CM/DIF阈值在125至2000 Hz范围内显著相关(r=0.77,p<0.01)。
  • 频率特异性相关性:125 Hz r=0.82,250 Hz r=0.74,500 Hz r=0.69,1000 Hz r=0.41,2000 Hz r=0.32。
  • 行为测听与CM/DIF阈值平均差异为0.4 dB(±14 dB)。

关键数值与推荐

  • CM/DIF阈值与行为阈值在低频(125、250、500 Hz)相关性较高,高频(1000、2000 Hz)相关性较低。
  • 平均差异0.4 dB(±14 dB)提示CM/DIF阈值与行为阈值接近。

临床怎么用

  • 对于难以进行行为测听的儿童人工耳蜗植入者,耳内耳蜗电图可提供客观的残留听力监测手段。
  • CM/DIF阈值在低频与行为阈值更接近,解读时应考虑频率特异性差异。

局限性

  • 高频(1000、2000 Hz)相关性较低,CM/DIF阈值在高频的可靠性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In adult cochlear implant patients, conventional audiometry is used to measure postoperative residual hearing which requires active listening and patient feedback. However, audiological measurements in pediatric cochlear implant patients are both challenging as well as time consuming. Intracochlear electrocochleography (ECOG) offers an objective and a time-efficient method to measure frequency-specific cochlear microphonic or difference thresholds (CM/DIF) thresholds that closely approximate auditory thresholds in adult cochlear implant patients. The correlation between CM/DIF and behavioral thresholds has not been established in pediatric cochlear implant patients. In the present study, CM/DIF thresholds were compared with audiometric thresholds in pediatric cochlear implant patients with postoperative residual hearing. DESIGN: Thirteen (11 unilateral and 2 bilateral) pediatric cochlear implant patients (mean age = 9.2 years ± 5.1) participated in this study. Audiometric thresholds were estimated using conventional, condition play, or visual reinforcement audiometry. A warble tone stimulus was used to measure audiometric thresholds at 125, 250, 500, 1000, and 2000 Hz. ECOG waveforms were elicited using 50-msec acoustic tone-bursts. The most apical intracochlear electrode was used as the recording electrode with an extra-cochlear ground electrode. The ECOG waveforms were analyzed to determine CM/DIF thresholds that were compared with pediatric cochlear implant patients' audiometric thresholds. RESULTS: The results show a significant correlation (r = 0.77, p < 0.01) between audiometric and CM/DIF thresholds over a frequency range of 125 to 2000 Hz in pediatric cochlear implant patients. Frequency-specific comparisons revealed a correlation of 0.82, 0.74, 0.69, 0.41, and 0.32 between the audiometric thresholds and CM/DIF thresholds measured at 125, 250, 500, 1000, and 2000 Hz, respectively. An average difference of 0.4 dB (±14 dB) was measured between the audiometric and CM/DIF thresholds. CONCLUSIONS: Intracochlear ECOG can be used to measure CM/DIF thresholds in pediatric cochlear implant patients with residual hearing in the implanted ear. The CM/DIF thresholds are similar to the audiometric thresholds at lower test frequencies and offer an objective method to monitor residual hearing in difficult-to-test pediatric cochlear implant patients.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Coulthurst S, Nachman AJ, Murray MT, et al. Comparison of Pure-Tone Thresholds and Cochlear Microphonics Thresholds in Pediatric Cochlear Implant Patients. Ear Hear. 2020. PMID: 32332587. doi:10.1097/AUD.0000000000000870

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。