术中无法诱发ECAP的成人人工耳蜗植入者术后言语识别表现
该回顾性病例复习在学术三级中心纳入2010年5月至2018年9月接受人工耳蜗植入、术中虽耳蜗内电极位置正确但无法获得ECAP反应的18岁以上患者。383例人工耳蜗植入中14例患者共15耳无法获得术中ECAP,术后6至12个月HINT平均分57.8%±37.8%,较术前平均提高42.6%±35.6%(95%CI 22.0%-63.1%,P=.001)。结论认为此类患者术后效果差异大,可从仅能感知声音到HINT满分100%。
要点
- 术中无ECAP反应者术后仍可能获得显著言语识别改善。
- 术后6至12个月HINT平均分57.8%,较术前提高42.6%。
- 此类患者术后效果差异大,可从仅感知声音到HINT 100%。
核心结论
- 术中无法获得ECAP反应的成人人工耳蜗植入者术后表现范围宽,可从声音感知到HINT评分100%。
研究设计与样本
- 回顾性病例复习,学术三级中心,2010年5月至2018年9月接受人工耳蜗植入的18岁及以上患者。
- 383例人工耳蜗植入中14例患者共15耳术中无法获得ECAP反应且耳蜗内电极位置正确。
主要发现
- 无ECAP组平均±标准差年龄61.7±15.7岁,术前平均PTA为103.5±17.0 dB。
- 12耳术前WRS为0%,9耳术前HINT评分为0%。
- 术后6至12个月平均HINT评分为57.8%±37.8%,较术前平均提高42.6%±35.6%(95%CI 22.0%-63.1%,P=.001,配对Student t检验)。
临床怎么用
- 对术中无ECAP反应但电极位置正确的成人患者,不应仅凭术中ECAP结果预判术后效果。
局限性
- 回顾性病例复习,样本量小(14例患者15耳),来自单中心。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To describe cochlear implant performance outcomes in adult patients in whom no intraoperative electrically evoked compound action potential (ECAP) responses were able to be obtained despite intracochlear electrode placement. STUDY DESIGN: Retrospective case review. SETTING: Academic tertiary center. SUBJECTS AND METHODS: Patients 18 years of age and older undergoing cochlear implantation between May 2010 and September 2018 with absent ECAP measurements intraoperatively with intracochlear electrode positioning were identified. Patient performance on sentence recognition testing using the Hearing in Noise Test (HINT) and AzBio at 6 to 12 months postoperatively was compared to preimplantation scores. Additional collected data included patient demographics, etiology of hearing loss, and preoperative pure-tone average (PTA) and word recognition scores (WRSs). RESULTS: Intraoperative ECAP measurements were unable to be obtained in 15 cochlear implants performed on 14 patients out of 383 cochlear implant cases. Of the patients with absent ECAP measures, the mean ± SD age was 61.7 ± 15.7 years. Causes of hearing loss included congenital hearing loss, meningitis, autoimmune inner ear disease, otosclerosis, presbycusis, and Ménière's disease. The average preoperative PTA was 103.5 ± 17.0 dB. Twelve implanted ears had a WRS of 0% and 9 had a HINT score of 0% prior to surgery. The mean HINT score at 6 to 12 months postimplantation was 57.8% ± 37.8% and had improved by 42.6% ± 35.6% compared to the mean preimplantation HINT score (95% confidence interval, 22.0%-63.1%, P = .001, paired Student t test). CONCLUSION: There is a wide range of cochlear implant performance in patients with absent intraoperative ECAP measures ranging from sound awareness to HINT scores of 100%.
引用
- Cooper T, Melder KL, Hyre R, et al. Cochlear Implant Performance in Adult Patients with Absent Intraoperative Electrically Evoked Compound Action Potentials. Otolaryngol Head Neck Surg. 2020. PMID: 32122228. doi:10.1177/0194599820907572
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。