文献速递耳科与耳神经

人工耳蜗植入对前庭诱发肌源性电位与宽频声导抗的影响

Effect of Cochlear Implantation on Vestibular Evoked Myogenic Potentials and Wideband Acoustic Immittance.
PubMed 文献 · Ear Hear · 2020-01-01

结果显示植入耳骨导VEMP反应率高于气导(仅眼性VEMP显著),低频吸光度降低;气导缺失而骨导存在的亚组低频吸光度下降最明显,提示机械性气骨导差而非前庭损失。

要点

  • 人工耳蜗植入耳骨导VEMP反应率高于气导,眼性VEMP差异显著。
  • 植入耳低频(500-1200 Hz)吸光度降低,提示系统硬度增加。
  • 气导VEMP缺失而骨导VEMP存在的耳低频吸光度下降最大,提示机械性气骨导差。

核心结论

  • 人工耳蜗植入耳骨导VEMP反应率高于气导VEMP反应率。
  • 植入耳低频吸光度变化提示系统变硬,在气导缺失而骨导存在的耳中最明显。
  • 该组机械性改变可导致气骨导差,使气导VEMP消失而非真正前庭损失。

研究设计与样本

  • 所有耳完成耳镜检查、听力学测试、226 Hz鼓室压测量、宽频声导抗(吸光度)、插入式耳机气导颈性和眼性VEMP及迷你振动器骨导振动VEMP测试。

主要发现

  • 正常听力耳对两种刺激的VEMP反应率均为100%。
  • 人工耳蜗植入耳骨导振动VEMP反应率高于气导刺激,颈性和眼性VEMP均如此,但仅眼性VEMP差异显著。
  • 人工耳蜗植入耳低频吸光度(500至1200 Hz)较正常听力耳降低。
  • 按VEMP反应模式分组后,气导缺失而骨导存在的组低频吸光度下降最大。

临床怎么用

  • 临床可考虑对人工耳蜗植入患者术前和术后使用骨导振动VEMP和宽频声导抗测试。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objective of this study was to determine if absent air conduction stimuli vestibular evoked myogenic potential (VEMP) responses found in ears after cochlear implantation can be the result of alterations in peripheral auditory mechanics rather than vestibular loss. Peripheral mechanical changes were investigated by comparing the response rates of air and bone conduction VEMPs as well as by measuring and evaluating wideband acoustic immittance (WAI) responses in ears with cochlear implants and normal-hearing control ears. The hypothesis was that the presence of a cochlear implant can lead to an air-bone gap, causing absent air conduction stimuli VEMP responses, but present bone conduction vibration VEMP responses (indicating normal vestibular function), with changes in WAI as compared with ears with normal hearing. Further hypotheses were that subsets of ears with cochlear implants would (a) have present VEMP responses to both stimuli, indicating normal vestibular function and either normal or near-normal WAI, or (b) have absent VEMP responses to both stimuli, regardless of WAI, due to true vestibular loss. DESIGN: Twenty-seven ears with cochlear implants (age range 7 to 31) and 10 ears with normal hearing (age range 7 to 31) were included in the study. All ears completed otoscopy, audiometric testing, 226 Hz tympanometry, WAI measures (absorbance), air conduction stimuli cervical and ocular VEMP testing through insert earphones, and bone conduction vibration cervical and ocular VEMP testing with a mini-shaker. Comparisons of VEMP responses to air and bone conduction stimuli, as well as absorbance responses between ears with normal hearing and ears with cochlear implants, were completed. RESULTS: All ears with normal hearing demonstrated 100% present VEMP response rates for both stimuli. Ears with cochlear implants had higher response rates to bone conduction vibration compared with air conduction stimuli for both cervical and ocular VEMPs; however, this was only significant for ocular VEMPs. Ears with cochlear implants demonstrated reduced low-frequency absorbance (500 to 1200 Hz) as compared with ears with normal hearing. To further analyze absorbance, ears with cochlear implants were placed into subgroups based on their cervical and ocular VEMP response patterns. These groups were (1) present air conduction stimuli response, present bone conduction vibration response, (2) absent air conduction stimuli response, present bone conduction vibration response, and (3) absent air conduction stimuli response, absent bone conduction vibration response. For both cervical and ocular VEMPs, the group with absent air conduction stimuli responses and present bone conduction vibration responses demonstrated the largest decrease in low-frequency absorbance as compared with the ears with normal hearing. CONCLUSIONS: Bone conduction VEMP response rates were increased compared with air-conduction VEMP response rates in ears with cochlear implants. Ears with cochlear implants also demonstrate changes in low-frequency absorbance consistent with a stiffer system. This effect was largest for ears that had absent air conduction but present bone conduction VEMPs. These findings suggest that this group, in particular, has a mechanical change that could lead to an air-bone gap, thus, abolishing the air conduction VEMP response due to an alteration in mechanics and not a true vestibular loss. Clinical considerations include using bone conduction vibration VEMPs and WAI for preoperative and postoperative testing in patients undergoing cochlear implantation.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Merchant GR, Schulz KM, Patterson JN, et al. Effect of Cochlear Implantation on Vestibular Evoked Myogenic Potentials and Wideband Acoustic Immittance. Ear Hear. 2020. PMID: 32032225. doi:10.1097/AUD.0000000000000831

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。