文献速递耳科与耳神经

全鼓膜置换鼓室成形术后高频传导性听力结果

High-Frequency Conductive Hearing following Total Drum Replacement Tympanoplasty.
PubMed 文献 · Otolaryngol Head Neck Surg · 2020-02-25

术后低频ABG平均降低15.5±13.3 dB(P<.001),而高频ABG变化不显著(降低2.6±16.2 dB,P=.450),提示高频传导性听力损失持续存在。

要点

  • 全鼓膜置换鼓室成形术后低频ABG显著改善。
  • 术后高频ABG无显著变化,高频传导性听力损失持续。
  • 常规ABG报告方法可能遗漏持续的高频ABG。

核心结论

  • 颞筋膜全鼓膜置换术后低频ABG改善,但高频传导性听力损失持续存在。

主要发现

  • 术前平均低频ABG为27.8±12.6 dB,平均高频ABG为21.5±15.1 dB(P=.044)。
  • 术后平均低频ABG显著降低15.5±13.3 dB(P<.001)。
  • 术后平均高频ABG降低2.6±16.2 dB,变化不显著(P=.450)。
  • 穿孔病因:外伤14例,慢性中耳炎9例。

临床怎么用

  • 临床报告鼓室成形术听力结果时,应关注高频ABG,避免仅依赖低频平均值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Conventional reporting of posttympanoplasty hearing outcomes use a pure-tone averaged air-bone gap (ABG) largely representing a low-frequency sound conduction. Few studies report high-frequency conductive hearing outcomes. Herein, we evaluate high-frequency ABG in patients following temporalis fascia total drum replacement. STUDY DESIGN: Case series with chart review. SETTING: Tertiary care center. SUBJECTS AND METHODS: All patients who underwent type 1 tympanoplasty using a lateral graft total drum replacement technique between August 2016 and February 2019 were identified. Patients with pre- and postoperative audiograms were included. Low-frequency ABG was calculated as the mean ABG at 250, 500, and 1000 Hz. High-frequency ABG was calculated at 4 KHz. Pre- and postoperative ABGs were compared. RESULTS: Twenty-three patients were included, and the mean age at surgery was 44 years (range, 9-68 years). Perforation etiology was from trauma (n = 14) or chronic otitis media (n = 9). Preoperative mean low-frequency ABG was 27.8 ± 12.6 dB and mean high-frequency ABG was 21.5 ± 15.1 dB (P = .044). Postoperatively, the mean low-frequency ABG was significantly reduced by 15.5 ± 13.3 dB (P < .001) while the mean high-frequency ABG insignificantly changed (reduced by 2.6 ± 16.2 dB, P = .450). CONCLUSION: In a series of patients undergoing temporalis fascia total drum replacement, low-frequency ABG improved; however, high-frequency conductive hearing loss persists. Conventional methods of reporting ABG may not identify persistent high-frequency ABG. These results merit further study across a range of tympanoplasty graft materials and surgical techniques.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Polanik MD, Trakimas DR, Black NL, et al. High-Frequency Conductive Hearing following Total Drum Replacement Tympanoplasty. Otolaryngol Head Neck Surg. 2020. PMID: 32097057. doi:10.1177/0194599820907600

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。