无耦合器直接植入卵圆窗的振动声桥临床经验
结果显示VSB助听后阈值和言语识别率改善,且无耦合器直接卵圆窗植入安全有效。
要点
- 无耦合器直接卵圆窗VSB植入可改善中重度混合性听力损失患者的助听后阈值。
- VSB助听下最舒适响度级显著低于助听器,言语识别率随时间改善。
- 部分病例在不使用VSB时气导阈值也有改善,但需进一步验证。
核心结论
- 无耦合器直接卵圆窗VSB植入听力结果良好且安全,可作为重度混合性听力损失听力康复的可靠选择。
主要发现
- 所有病例术中圆窗振动声桥植入困难,最终FMT无耦合器置于卵圆窗。
- 术前与术后骨导阈值无差异。
- VSB助听后阈值在功能增益和有效增益方面改善。
- 4例在不使用VSB时气导阈值改善。
- VSB助听下最舒适响度级显著低于助听器,且VSB助听下言语识别率随时间改善。
临床怎么用
- 对于圆窗振动声桥植入困难的重度混合性听力损失患者,可考虑无耦合器直接卵圆窗VSB植入。
局限性
- 回顾性研究,证据等级为4级。
- 样本量小(8例9耳)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: To investigate the efficacy of direct implantation of a Vibrant Soundbridge (VSB) implant in the oval window (OW) without the use of an OW coupler in patients with severe mixed hearing loss. STUDY DESIGN: Retrospective chart review METHODS: A total of 62 patients underwent VSB implantation between July 2016 and December 2018 at Severance Hospital in Seoul, South Korea. Among them, eight patients (nine ears) with moderate-to-severe mixed hearing loss were implanted with a VSB directly in the OW. A floating mass transducer (FMT) was attached to the stapes footplate and covered with tragal cartilage. The outcomes were evaluated using pure-tone audiogram and speech audiogram preoperatively and postoperatively. Word recognition score (WRS; % correct) were measured at the most comfortable loudness (MCL) level to evaluate speech perception. RESULTS: All cases posed difficulty with round window vibroplasty during surgery, and eventually, an FMT was appropriately placed in the OW without a coupler. Preoperative and postoperative bone conduction thresholds were not different. VSB-aided threshold improved in terms of functional and effective gains. Interestingly, four cases showed improved air conduction thresholds without the use of a VSB. In addition, MCL level with a VSB was significantly lower than that with a hearing aid, and VSB-aided WRS improved over time. CONCLUSIONS: Direct implantation of a VSB in the OW without the use of a coupler showed favorable hearing outcomes, and the OW vibroplasty was safe. Direct OW vibroplasty without a coupler is a reliable procedure and can be a good option for hearing rehabilitation in patients with severe mixed hearing loss. LEVEL OF EVIDENCE: 4 Laryngoscope, 2020.
引用
- Kwak SH, Moon YM, Nam GS, et al. Clinical Experience of Vibroplasty With Direct Coupling to the Oval Window Without Use of a Coupler. Laryngoscope. 2020. PMID: 31977072. doi:10.1002/lary.28514
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。