儿童人工耳蜗植入术后耳蜗内电耳蜗图:与听阈及听觉表现的关系
本研究在60例先天性听力损失儿童(102耳)人工耳蜗植入后2-5年,比较耳蜗内记录的电耳蜗图微音电位(CM)与行为听阈,并评估有无残余听力儿童的言语和听觉 outcomes。发现耳蜗性听力损失耳中CM与0.125-2 kHz行为听阈高度相关,而有残余CM者听觉表现更佳;但听神经病谱系障碍耳中CM阈值与行为听阈不匹配。
要点
- 耳蜗性听力损失儿童中,耳蜗内CM可可靠预测残余听阈。
- 听神经病谱系障碍儿童中,CM阈值与行为听阈不匹配。
- 术后可记录到CM(残余听力保留)的儿童听觉表现更佳。
核心结论
- 先天性耳蜗性听力损失儿童中,客观耳蜗内CM反应可可靠预测残余听阈。
- 听神经病谱系障碍儿童中,CM阈值与行为听阈不匹配。
- 术后可记录到CM(残余听力保留)的儿童表现出更好的CI结局。
研究设计与样本
- 研究在三级大学附属儿科医疗中心进行。
- 纳入60例儿童共102个植入耳,植入时年龄早,评估在术后2至5年。
- 采用耳蜗内电耳蜗图技术记录CM反应,并与0.125至2 kHz行为听阈相关分析。
- 所有儿童使用Advanced Bionics人工耳蜗(High Focus J1或MidScala电极),并接受植入前后广泛听觉康复。
- 收集言语空间与听觉质量量表、听觉能力分类量表及教育环境信息,比较有无残余CM反应儿童的CI结局。
主要发现
- 在88个诊断为耳蜗性听力损失的耳中,仅29耳获得清晰CM反应,其余耳在最大输出水平无CM反应。
- CM反应与0.125至2 kHz频率范围行为听阈高度相关,相关系数为0.7至0.83。
- 在14个诊断为听神经病谱系障碍的耳中,8耳有残余听力且术后可记录CM,另6耳在所有测试频率最大输出水平均无CM反应。
- 听神经病谱系障碍耳中CM反应 supposedly 优于行为听阈,但与测试频率阈值相关性差。
- 有残余听力的儿童相比无残余听力者,CI后听觉结局显著更好。
关键数值与推荐
- 耳蜗性听力损失耳(n=88)中29耳可记录清晰CM,其余无CM反应。
- CM与行为听阈相关系数0.7至0.83(0.125-2 kHz)。
- 听神经病谱系障碍耳(n=14)中8耳有残余听力并可记录CM,6耳无CM反应。
临床怎么用
- 术后耳蜗内CM可用于辅助评估耳蜗性听力损失儿童的残余听阈。
- 对听神经病谱系障碍儿童,CM阈值不能替代行为听阈评估。
- 术后可记录CM提示残余听力保留,与更好的CI听觉结局相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of this study was to compare intracochlear-recorded cochlear microphonics (CM) responses to behavioral audiometry thresholds in young children, with congenital hearing loss, 2 to 5 years after cochlear implantation early in life. In addition, differences in speech and auditory outcomes were assessed among children with and without residual hearing. DESIGN: The study was conducted at a tertiary, university-affiliated, pediatric medical center. CM responses by intracochlear electrocochleography technique were recorded from 102 implanted ears of 60 children and those responses correlated to behavioral audiometry thresholds at 0.125 to 2 kHz frequencies. All children had received Advanced Bionics cochlear implant with High Focus J1 or MidScala electrodes, along with extensive auditory rehabilitation before and after implantation, including the use of conventional hearing aids. Speech Spatial and Hearing Qualities, Category of Auditory Performance scale, and educational settings information were obtained for each participant. Those cochlear implantation (CI) outcomes were compared between children with or without residual CM responses. RESULTS: Two distinctive CM responses patterns were found among the implanted children. Of all ears diagnosed with cochlear hearing loss (n = 88), only in 29 ears, clear CM responses were obtained. In all other ears, no CM responses were obtained at the maximum output levels. The CM responses were highly correlated with coefficients ranging from 0.7 to 0.83 for the audiometric behavioral thresholds at 0.125 to 2 kHz frequency range. Of all ears diagnosed with auditory neuropathy syndrome disorder (n = 14), eight ears had residual hearing and recordable CM postimplantation. The other six ears showed no recordable CM responses at maximum output levels for all tested frequencies. Those showed supposedly better CM responses than the behavioral audiometry threshold, however with poor correlations with tested frequency thresholds. Children with residual hearing showed significantly better auditory outcomes with CI, compared with those without residual hearing. CONCLUSIONS: In children with congenital cochlear hearing loss, the objective CM intracochlear responses can reliably predict the residual audiometric threshold. However, in children with auditory neuropathy syndrome disorder, the CM thresholds did not match the behavioral audiometric responses. Postoperatively, children with recordable CM responses, showing preserved residual hearing, demonstrated better CI outcomes.
引用
- Attias J, Ulanovski D, Hilly O, et al. Postoperative Intracochlear Electrocochleography in Pediatric Cochlear Implant Recipients: Association to Audiometric Thresholds and Auditory Performance. Ear Hear. 2020. PMID: 31977726. doi:10.1097/AUD.0000000000000833
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。