文献速递咽喉与嗓音

高速喉镜声门面积波形测量的分节者间变异性

Intersegmenter Variability in High-Speed Laryngoscopy-Based Glottal Area Waveform Measures.
PubMed 文献 · Laryngoscope · 2019-12-16

本研究评估高速视频内窥镜(HSV)声门面积波形(GAW)测量中不同分节者间的变异性。20例正常及发声障碍受试者的HSV视频由三名训练有素的分节者独立分割,计算46项GAW测量的组内相关系数(ICC)。结果显示ICC总体高度可接受,表明GAT软件在临床客观定量评估中可靠。

要点

  • 46项GAW测量中,38项ICC>0.9,7项0.75-0.9,1项0.5-0.75。
  • 分节者间差异小,对临床评估结果影响不明显。
  • 建议临床应用前进行分割训练以保证软件性能。

核心结论

  • 高ICC值证实GAT用于HSV客观定量评估的临床适用性。
  • 手动或半自动分割对临床评估结果无明显影响。

研究设计与样本

  • 队列研究,评估评分者信度。
  • 选取20例正常发声及发声障碍受试者的HSV视频,由三名训练有素的分节者独立分割声门区域。

主要发现

  • 46项GAW测量的ICC总体高度可接受。
  • 1项参数ICC为中等(0.5<ICC<0.75),7项为良好(0.75<ICC<0.9),38项为优秀(ICC>0.9)。

关键数值与推荐

  • ICC分类标准:中等0.5-0.75,良好0.75-0.9,优秀>0.9。
  • 证据等级:2b。

临床怎么用

  • GAT可用于HSV的客观定量评估。
  • 临床应用前建议进行分割训练。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: High-speed videoendoscopy (HSV) has potential to objectively quantify vibratory vocal fold characteristics during phonation. Glottal Analysis Tools (GAT) version 2018, developed in Erlangen, Germany, is software for determining various glottal area waveform (GAW) quantities. Before having GAT analyze HSV videos, segmenters have to define glottis manually across videos in a semiautomatic segmentation protocol. Such interventions are hypothesized to induce variability of subsequent GAW measure computation across segmenters and may attenuate GAT measures' reliability to a certain point. This study explored intersegmenter variability in GAT's GAW measures based on semiautomatic image processing. STUDY DESIGN: Cohort study of rater reliability. METHODS: In total, 20 HSV videos from normophonic and dysphonic subjects with various laryngeal disorders were selected for this study and segmented by three trained segmenters. They separately segmented glottis areas in the same frame sets of the videos. Upon analysis of GAW, GAT offers 46 measures related to topologic GAW dynamic characteristics, GAW periodicity and perturbation characteristics, and GAW harmonic components. To address GAT's reliability, intersegmenter-based variability in these measures was examined with intraclass correlation coefficient (ICC). RESULTS: In general, ICC behavior of the 46 GAW measures across three raters was highly acceptable. ICC of one parameter was moderate (0.5 < ICC < 0.75), good for seven parameters (0.75 < ICC < 0.9), and excellent for 38 parameters (0.9 < ICC). CONCLUSIONS: Overall, high ICC values confirm clinical applicability of GAT for objective and quantitative assessment of HSV. Small intersegmenter differences with actual small parameter differences suggest that manual or semiautomatic segmentation in GAT does not noticeably influence clinical assessment outcome. To guarantee the software's performance, we suggest segmentation training before clinical application. LEVEL OF EVIDENCE: 2b Laryngoscope, 130:E654-E661, 2020.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Maryn Y, Verguts M, Demarsin H, et al. Intersegmenter Variability in High-Speed Laryngoscopy-Based Glottal Area Waveform Measures. Laryngoscope. 2019. PMID: 31840827. doi:10.1002/lary.28475

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。