日常实践中扩展传统患者描述的应用价值与可行性
该前瞻性研究评估了常规患者描述对疾病特异性验证工具结果的预测准确性,以及电子系统采集患者报告健康状态的可行性。结果显示,常规描述预测准确性有限,但电子采集完成率高且节省医生时间。
要点
- 常规患者描述对验证工具结果的预测准确性有限。
- 电子系统采集患者报告完成率达91%。
- 电子采集估计每例患者节省医生11分钟。
核心结论
- 常规患者描述不能准确预测疾病特异性验证工具结果。
- 电子系统采集患者报告健康状态在门诊实践中可行。
研究设计与样本
- 前瞻性评估连续符合条件的门诊患者。
- 第一目标比较常规症状描述与验证工具应答。
- 第二目标评估电子系统采集的可行性。
主要发现
- 听力损失、咽鼓管功能障碍、鼻塞和慢性鼻窦炎患者的ROC曲线下面积为0.38至0.83。
- Spearman ρ相关系数为0.25至0.46。
- 敏感性和特异性范围为15.9%至87.8%,正确分类率为42.3%至55.2%。
- 电子问卷完成率为91%。
- 新患者完成时间为7:18至12:37,复诊患者为3:23至6:41。
临床怎么用
- 在门诊中可考虑使用电子系统采集患者报告的健康状态。
- 不应仅依赖常规患者描述来预测验证工具结果。
局限性
- 研究结论指出这些主题需要进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: Institutional and national programs have endorsed the use of validated instruments in daily practice, but their utility for frontline clinicians is unknown. Our first objective was thus to determine if routinely obtained patient descriptions accurately predict disease-specific validated instrument results. Our second objective was to assess the feasibility of deploying an electronic system to obtain and document patient-reported descriptions of health status. STUDY DESIGN: Prospective assessment of consecutive eligible ambulatory care patients. METHODS: For the first objective, patients presenting with the same chief complaint at consecutive visits provided concurrent routine symptom descriptions and validated instrument responses. To determine whether patients' routine descriptions predicted scores from disease-specific instruments, receiver operator characteristic (ROC) curves, sensitivity/specificity, Spearman ρ correlation, and regression models were utilized. For the second objective, feasibility assessment focused on percent with successful response capture, time to questionnaire completion, and impact on physician time needed to obtain and document patient histories. RESULTS: For the first objective, among patients with hearing loss, eustachian tube dysfunction, nasal obstruction, and chronic rhinosinusitis, the areas under the ROC curves were 0.38 to 0.83. Spearman ρ coefficients were 0.25 to 0.46. Sensitivity and specificity ranged from 15.9% to 87.8%, with correct classification in 42.3% to 55.2% of cases. For the second objective, there was a 91% completion rate. Completion times were 7:18 to 12:37 for new patients and 3:23 to 6:41 for established patients. Physician time savings were estimated at 11 minutes per patient. CONCLUSIONS: Using validated instruments and electronic data collection systems in daily practice has practical and clinical implications. These topics warrant further study. LEVEL OF EVIDENCE: 2c Laryngoscope, 130:S1-S13, 2020.
引用
- Shin JJ, Carroll TL, Prince AA, et al. The Utility and Feasibility of Extending Beyond Traditional Patient Descriptions in Daily Practice. Laryngoscope. 2019. PMID: 31876293. doi:10.1002/lary.28467
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。