文献速递耳科与耳神经小儿耳鼻咽喉

圆润插入技术用于囊性内耳畸形人工耳蜗植入

Rounded Insertion Technique for Cochlear Implantation Surgery to Treat Cystic Inner Ear Malformation.
PubMed 文献 · Laryngoscope · 2019-12-04

本文回顾性分析7例(9耳)囊性内耳畸形(耳蜗发育不全和/或共同腔)患者,采用圆润插入技术行人工耳蜗植入,术后X线确认电极位置,调机确认功能电极数。结果显示手术均无并发症,囊性耳蜗内最大数量电极接触功能良好,提示该技术安全可靠。

要点

  • 圆润插入技术适用于耳蜗发育不全和/或共同腔的囊性内耳畸形患者。
  • 该技术可插入最大数量电极并防止电极误入内听道。
  • 小样本回顾性研究显示手术安全、电极功能良好。

核心结论

  • 圆润插入技术对耳蜗发育不全和/或共同腔患者的人工耳蜗植入安全可靠。

研究设计与样本

  • 回顾性病历分析连续纳入的耳蜗发育不全和/或共同腔行人工耳蜗植入患者,共7例(9耳),男5例、女2例,中位年龄3岁(范围2-7岁)。

主要发现

  • 7例中4例右侧植入、1例左侧、2例双侧;9耳中6耳为耳蜗发育不全、3耳为共同腔。
  • 所有经圆润插入技术的人工耳蜗植入手术均无并发症完成。
  • 术后X线及调机确认囊性耳蜗内最大数量电极接触功能良好。

关键数值与推荐

  • 术后通过X线确认电极阵列位置,调机过程确认功能电极数量。
  • 证据等级为4级。

临床怎么用

  • 对耳蜗发育不全和/或共同腔的囊性内耳畸形患者,可考虑采用圆润插入技术以最大化功能电极数量并避免电极误入内听道。

局限性

  • 回顾性设计、样本量小(7例9耳),证据等级为4级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This article outlines the advantages and applicability of the rounded insertion technique of cochlear implants in patients with cystic inner ear malformation. This technique enables the insertion of the maximum number of electrodes and prevents the unwanted entry of electrodes into the internal auditory canal. METHODS: We conducted a retrospective chart review of consecutive patients with cochlear hypoplasia (CH) and/or common cavity (CC) who underwent CI (cochlear implantation) via rounded insertion technique. The position of the electrode array in each patient was confirmed postoperatively via X-ray, and the number of functional electrodes was confirmed during the mapping process. RESULTS: This study included five male and two female patients (median age: 3 years; age range: 2-7 years). Among the seven patients, four received a cochlear implant on the right side, one on the left side, and two bilaterally. Of the nine ears, six were cases of CH, and three were CC. All cochlear implant surgeries via rounded insertion technique were completed without complications. The maximum number of electrode contacts with fair function in the cystic cochlea was confirmed via postoperative X-ray and the subsequent mapping process. CONCLUSION: This consecutive series of patients demonstrated the safety and reliability of rounded insertion technique for CI in patients with CH and/or CC. LEVEL OF EVIDENCE: 4 Laryngoscope, 130:2229-2233, 2020.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Hu HC, Chen WK, Huang MJ, et al. Rounded Insertion Technique for Cochlear Implantation Surgery to Treat Cystic Inner Ear Malformation. Laryngoscope. 2019. PMID: 31800101. doi:10.1002/lary.28425

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。