耳鼻咽喉科医生口咽HPV职业暴露研究
该研究通过动物与人类实验室模型,评估电灼烟雾中HPV16 DNA气溶胶化是否使耳鼻咽喉科医生面临暴露风险。将表达HPV p16 E6/E7基因的质粒注射小鼠尾部后电灼,并采集6例经口机器人手术患者电灼烟雾及术者口罩、吸引装置、机器人臂样本。结果显示所有样本均未检出HPV16 DNA,认为经电灼烟雾的职业暴露风险可能极小。
要点
- 电灼烟雾中未检出HPV16 DNA,职业暴露风险可能极小。
- 小鼠尾部电灼及患者手术烟雾样本均无HPV16 DNA。
- 术者口罩、吸引装置和机器人臂也未检出HPV16 DNA。
核心结论
- 经电灼烟雾的职业暴露于HPV16的风险可能极小。
研究设计与样本
- 动物与人类实验室模型,包括小鼠尾部电灼实验和6例经口机器人手术患者术中采样。
主要发现
- 小鼠尾部电灼烟雾样本均未检出HPV16 DNA。
- 6例患者(3例p16阴性、3例p16阳性)电灼烟雾样本均未检出HPV16 DNA。
- 术者口罩、吸引装置和机器人臂样本均未检出HPV16 DNA。
关键数值与推荐
- PCR检测灵敏度为1.5 ng E6E7 DNA。
- 质粒注射量为2 μg DNA in 20 μL TE缓冲液。
- 电灼时间为5至10秒。
临床怎么用
- 耳鼻咽喉科医生进行电灼操作时,经烟雾暴露HPV16的风险可能极小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: Human papillomavirus (HPV) is a DNA virus that causes cancer in multiple sites. Although sexual activity is the primary means of oropharyngeal HPV acquisition, studies suggest HPV transmission through occupational exposure from medical instruments and surgical fumes. We assess if aerosolization of HPV16 DNA via electrocautery places otolaryngologists at risk for exposure. STUDY DESIGN: Animal and human laboratory model. METHODS: Plasmid (pLXSN16E6E7) expressing HPV p16 E6/E7 genes was transformed into DH5α Escherichia coli cells using the heat shock method. Miniprep and maxiprep purification of transformed DNA with subsequent restriction enzyme double digestion confirmed presence of E6E7 fragment. We injected 2 μg plasmid DNA in 20 μL TE (Tris and ethylenediaminetetraacetic acid) buffer intradermally into freshly severed mouse tail then cauterized for 5 to 10 seconds. Generated fumes were collected through a suction tube fitted with Whatman filter paper. Filter paper was placed in 100 μL TE buffer. Additionally, six patients undergoing transoral robotic surgery for resection of oropharyngeal cancer were identified, three with p16-negative tumors and three with p16-positive tumors. Intraoperatively, Whatman filter paper was exposed to electrocautery fumes, then placed in 100 uL TE buffer. Additional samples were collected from the suction tubing and filter, the surgical mask of the surgeon at head of the bed, and the robot arm. RESULTS: Samples were analyzed via polymerase chain reaction with an assay sensitivity of 1.5 ng E6E7 DNA. None of the patient or mouse tail samples yielded detectable HPV16 DNA in the electrocautery fumes. We did not detect HPV16 DNA on the surgical masks, suction apparatus, or robot arm intraoperatively. CONCLUSIONS: There is likely minimal risk of occupational exposure to HPV16 via electrocautery fumes. LEVEL OF EVIDENCE: NA Laryngoscope, 130:2366-2371, 2020.
引用
- Subbarayan RS, Shew M, Enders J, et al. Occupational exposure of oropharyngeal human papillomavirus amongst otolaryngologists. Laryngoscope. 2019. PMID: 31710711. doi:10.1002/lary.28383
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。