文献速递咽喉与嗓音

兔模型中使用自体带蒂脂肪瓣进行声带重建

Vocal Fold Reconstruction Using an Autologous Pedicled Fat Flap in a Rabbit Model.
PubMed 文献 · Laryngoscope · 2019-11-29

本研究在30只雄性新西兰白兔中评估血管化自体带蒂脂肪瓣(PEFA)重建声带的有效性,20只行右侧喉返神经切除并同期PEFA重建,10只为正常对照。组织学显示PEFA组与对照组固有层比例和声带总像素数相似,振动分析示PEFA组最大振幅差异稍低,但动态声门间隙无显著差异。结论认为PEFA瓣重建能维持声带面积且不显著降低声带振动。

要点

  • PEFA瓣重建后声带固有层比例与正常对照组相似。
  • PEFA组声带振动最大振幅稍低于对照组。
  • 两组动态声门间隙无显著差异。

核心结论

  • PEFA瓣声带重建技术在兔模型中能维持声带面积且不显著降低声带振动。

研究设计与样本

  • 动物模型研究,纳入30只雄性新西兰白兔,20只行PEFA重建(PEFA组),10只为正常对照(对照组)。

主要发现

  • 组织学显示PEFA组与对照组的固有层比例(固有层像素/声带总像素)和声带总像素数相似。
  • 振动分析显示PEFA组最大振幅差异稍低于对照组。
  • PEFA组与对照组的动态声门间隙无显著差异。

关键数值与推荐

  • PEFA瓣包含会厌前脂肪和甲状软骨膜,通过甲状软骨下缘开窗植入。
  • 重建后1个月进行组织学和高速度视频振动分析。

临床怎么用

  • 该技术可能为声带麻痹提供一种维持声带面积且不显著损害振动的重建选择,但需进一步临床验证。

局限性

  • 研究为兔模型,样本量有限(30只),结果外推至人类需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: We evaluated the efficacy of a vocal fold reconstruction technique using a vascularized autologous pedicled fat (PEFA) flap in a rabbit model of vocal fold paralysis. STUDY DESIGN: Animal model. METHODS: The study included 30 male New Zealand White rabbits; 20 received vocal fold reconstructions (PEFA group) and 10 served as normal controls (control group). The right recurrent laryngeal nerve was resected, and simultaneous PEFA flap reconstruction was performed. The PEFA flap, including a pre-epiglottic fat and thyroid perichondrium, was elevated and implanted through a window at the inferior border of the thyroid cartilage. Histological and high-speed video analyses of vocal fold vibration were performed 1 month after PEFA reconstruction. The maximum amplitude of vocal fold vibration and the dynamic glottal gap were used to assess vocal fold vibration. RESULTS: The histological findings showed that the lamina propria ratio (lamina propria pixels/total vocal fold pixels) and the total number of vocal fold pixels were similar between the PEFA and control groups. Vocal fold vibration analyses indicated that the maximum amplitude differences in the vibration were slightly lower in the PEFA group. However, the dynamic glottal gap of the vocal fold was not significantly different between the PEFA group and the control group. CONCLUSIONS: The PEFA flap vocal fold reconstruction technique maintained the vocal fold area without a significant reduction in vocal fold vibration in a rabbit model. LEVEL OF EVIDENCE: NA Laryngoscope, 130:1770-1774, 2020.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Lee S, Seon S, Park K, et al. Vocal Fold Reconstruction Using an Autologous Pedicled Fat Flap in a Rabbit Model. Laryngoscope. 2019. PMID: 31782801. doi:10.1002/lary.28303

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。