文献速递鼻科小儿耳鼻咽喉

三维打印鼻内镜手术模拟器的有效性验证

Validity testing of a three-dimensionally printed endoscopic sinonasal surgery simulator.
PubMed 文献 · Laryngoscope · 2019-11-12

本研究前瞻性纳入12名耳鼻咽喉科住院医师,在PHACON鼻窦手术模拟器及尸体头上操作并录像,由外部鼻科专家用经验证的全量表评分。结果显示模型在表面、内容、结构和并发效度上均获验证,但黏膜与骨组织真实感及额筛区解剖需改进。

要点

  • 三维打印鼻窦手术模拟器在结构和并发效度上获验证
  • 75%参与者认为解剖结构外观真实,黏膜和骨组织仅30%和41.7%认为真实
  • 91.7%认为模型有助于解剖教学,66.7%认为有助于手术技术教学

核心结论

  • 三维打印鼻窦手术模拟器在表面、内容、结构和并发效度上均获验证,可作为住院医师鼻内镜手术培训工具,但黏膜质量和额筛区模拟解剖需改进。

研究设计与样本

  • 前瞻性队列研究,纳入12名耳鼻咽喉科住院医师,在模拟器及尸体头上操作并录像,由外部鼻科专家用全量表评分,同时用5点Likert量表问卷评估表面和内容效度。

主要发现

  • 75%参与者认为解剖结构外观真实,30%认为黏膜组织真实,41.7%认为骨组织真实。
  • 91.7%参与者认为模型有助于解剖教学,66.7%认为有助于手术技术教学。
  • 新手与经验组操作表现差异显著,证实结构效度。
  • 模型操作表现与尸体头金标准操作表现显著相关,证实并发效度。

关键数值与推荐

  • 表面效度:75%参与者认为解剖结构外观真实。
  • 内容效度:91.7%认为模型有助于解剖教学,66.7%认为有助于手术技术教学。
  • 结构效度:新手与经验组表现差异显著。
  • 并发效度:模型与尸体头操作表现显著相关。

临床怎么用

  • 该模拟器可用于耳鼻咽喉科住院医师鼻内镜手术培训,尤其适合解剖教学和基本操作技术训练。
  • 使用中需注意模拟黏膜和骨组织真实感不足,额筛区解剖模拟有待改进。

局限性

  • 样本量较小,仅纳入12名住院医师。
  • 黏膜和骨组织真实感评价较低,额筛区解剖模拟需改进。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: To assess the face, content, construct, and concurrent validity of the PHACON Sinonasal Surgery Simulator (SNSS). STUDY DESIGN: Prospective cohort study. METHODS: A total of 12 otolaryngology residents were recruited to perform sinonasal surgery on the simulator followed by cadaveric heads. Resident performances were recorded and de-identified. Face and content validities were evaluated based on 5-point Likert scale questionnaires. The recordings were evaluated by extramural expert rhinologists based on a validated Global Rating Scale (GRS). These results were analyzed and compared to assess construct and concurrent validity. RESULTS: The appearance of anatomic structures was rated as realistic by 75% of all participants, while only 30% and 41.7% rated the mucosal and bony tissues as realistic, respectively. A total of 91.7% of participants found the model useful for teaching anatomy, while 66.7% said it was useful for teaching operative technique. Construct validity was confirmed by showing significant differences in performance between the novice and experienced groups. Concurrent validity was confirmed by showing significant correlation between performance on the model and gold standard (i.e. cadaver head). CONCLUSIONS: This study demonstrates the face, content, concurrent, and construct validity of a 3D-printed SNSS. Although this model has the potential to be a valuable tool in endoscopic sinus surgery training for otolaryngology residents, improvements are required with respect to the quality of simulated mucosal tissue as well as the simulated anatomy of the fronto-ethmoid compartment Level of Evidence: NA Laryngoscope, 2019.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Alwani MM, Svenstrup TJ, Bandali EH, et al. Validity testing of a three-dimensionally printed endoscopic sinonasal surgery simulator. Laryngoscope. 2019. PMID: 31714604. doi:10.1002/lary.28356

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。