文献速递鼻科

拧干后麻黄素棉片残留1:1000肾上腺素约1mg

Approximate Weight of 1:1000 Topical Epinephrine on Wrung-Out Epinephrine-Soaked Pledgets.
PubMed 文献 · Otolaryngol Head Neck Surg · 2019-11-19

OBJECTIVE: Topical 1:1000 epinephrine solution is commonly applied intranasally with cottonoid pledgets in endoscopic sinonasal surgery for local vasoconstriction and hemostasis. Pledgets are typically submerged in epinephrine solution and applied without measurement.…

要点

  • 拧干后的0.5×3英寸棉片残留肾上腺素约1mg
  • 临床使用拧干棉片可量化肾上腺素暴露量

核心结论

  • 0.5×3英寸棉片浸入1:1000肾上腺素后拧干,约吸收1mg肾上腺素,与浸泡时间(0至5分钟)无关。

主要发现

  • 拧干后棉片平均肾上腺素残留量为0.931mg。
  • 浸泡0、1、5分钟后拧干的平均残留量分别为0.914、0.913、0.967mg。

关键数值与推荐

  • 1:1000肾上腺素溶液浓度为1mg/mL。
  • 棉片规格为0.5英寸×3英寸。
  • 拧干后棉片平均肾上腺素量为0.931mg。
  • 浸泡时间0、1、5分钟对应平均残留量0.914、0.913、0.967mg。

临床怎么用

  • 鼻内镜手术中使用拧干的肾上腺素棉片时,可预期每块棉片约含1mg肾上腺素,便于评估 hemodynamic 风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Topical 1:1000 epinephrine solution is commonly applied intranasally with cottonoid pledgets in endoscopic sinonasal surgery for local vasoconstriction and hemostasis. Pledgets are typically submerged in epinephrine solution and applied without measurement. Hemodynamic complications have been reported when pledgets have been saturated and not wrung out. The amount of epinephrine absorbed per pledget has not been studied methodically. The purpose of this study was to determine the amount of topical 1:1000 epinephrine remaining on a cottonoid pledget after wringing out the pledget, to simulate intraoperative application. STUDY DESIGN: Cohort study. SETTING: Tertiary care center. SUBJECTS AND METHODS: Sixty 0.5-in × 3-in cottonoid pledgets were submerged in canisters filled with 1:1000 epinephrine solution (1 mg/mL). Weights of the epinephrine-filled canisters were measured before submerging the pledgets and then after removing and wringing out the pledgets. Measurements were recorded for each pledget after being submerged for 0, 1, and 5 minutes and then wrung out. Mean weights were calculated and compared between the submersion durations. RESULTS: The mean overall weight of epinephrine on a wrung-out pledget was 0.931 mg. Mean weights of epinephrine absorbed onto wrung-out pledgets after submersion for 0, 1, and 5 minutes were 0.914, 0.913, and 0.967 mg, respectively. There were no significant differences in weights based on submersion duration (P = .296). CONCLUSION: Approximately 1 mg of epinephrine was absorbed onto 0.5-in × 3-in cottonoid pledgets when pledgets were wrung out after being submerged in 1:1000 epinephrine, whether being removed from solution immediately or after up to 5 minutes.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Kuhar HN, Han X, Penning DH, et al. Approximate Weight of 1:1000 Topical Epinephrine on Wrung-Out Epinephrine-Soaked Pledgets. Otolaryngol Head Neck Surg. 2019. PMID: 31739741. doi:10.1177/0194599819888651

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。