文献速递耳科与耳神经

人工耳蜗植入者的宽频声导抗:反射率与镫骨肌反射

Wideband Acoustic Immittance in Cochlear Implant Recipients: Reflectance and Stapedial Reflexes.
PubMed 文献 · Ear Hear · 2020-01-01

研究对比人工耳蜗植入耳与正常中耳功能耳的宽频功率反射率,并描述电诱发镫骨肌反射引起的反射率变化。结果显示植入耳在部分频率反射率显著更高,反射阈值用宽频探头测量在部分条件下更低但未达统计学显著。

要点

  • 人工耳蜗植入耳在250-891 Hz和4238-4490 Hz平均反射率显著高于正常对照。
  • 电诱发镫骨肌反射在14耳中9耳(64.3%)、46个电极中24个(52.5%)可测。
  • 反射激活对≥1000 Hz反射率影响最大,宽频或678 Hz探头比226 Hz更常测得反射。

核心结论

  • 宽频声导抗测量(反射率与反射)应同样考虑用于人工耳蜗植入耳。
  • 植入耳反射率模式与中耳静息刚度增加一致,但个体曲线变异大。

研究设计与样本

  • 同侧反射用三种探头测量:宽频啁啾(200-8000 Hz)、226 Hz纯音和678 Hz纯音。
  • 以28名无人工耳蜗且中耳功能正常的成人的宽频反射率作为正常参照。

主要发现

  • 植入耳平均反射率在250-891 Hz和4238-4490 Hz显著高于正常参照组。
  • 部分植入耳226 Hz声导纳低,可能贡献了组间差异,因对照组按设计226 Hz声导纳临床正常。
  • 电诱发镫骨肌反射在9/14耳(64.3%)和24/46电极(52.5%)中可测。
  • 反射诱导的反射率变化模式因人/耳而异,但同一耳内不同电极间相似。
  • 反射激活对≥1000 Hz反射率影响最大,即使226 Hz声导纳临床正常的耳也如此。

临床怎么用

  • 对人工耳蜗植入者评估中耳功能时,可考虑采用宽频声导抗测量反射率和反射。
  • 使用宽频或678 Hz探头可能比226 Hz探头更易测得电诱发镫骨肌反射。

局限性

  • 需进一步研究植入耳随时间的变化,以更全面理解提示中耳刚度增加的反射率模式并优化宽频探头测量电诱发镫骨肌反射。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: to characterize differences in wideband power reflectance for ears with and without cochlear implants (CIs), to describe electrically evoked stapedial reflex (eSR)-induced changes in reflectance, and to evaluate the benefit of a broadband probe for reflex threshold determination for CI recipients. It was hypothesized that reflectance patterns in ears with CIs would be consistent with increased middle ear stiffness and that reflex thresholds measured with a broadband probe would be lower compared with thresholds obtained with a single-frequency probe. DESIGN: Eleven CI recipients participated in both wideband reflectance and eSR testing. Ipsilateral reflexes were measured with three probes: a broadband chirp (swept from 200 to 8000 Hz), a 226 Hz tone, and a 678 Hz tone. Wideband reflectance measures acquired from 28 adults without CIs and with normal middle ear function served as a normative data set for comparison. RESULTS: Considering the group data, average reflectance was significantly greater for ears with CIs across 250 to 891 Hz and 4238 to 4490 Hz compared with the normative data set, although individual reflectance curves were variable. Some CI recipients also had low 226 Hz admittance, which contributed to the group finding, considering the control group had clinically normal 226 Hz admittance by design. Electrically evoked stapedial reflexes were measurable in nine of 14 ears (64.3%) and in 24 of 46 electrodes (52.5%) tested. Reflex-induced changes in reflectance patterns were unique to the participant/ear, but similar across activators (electrodes) within a given ear. In addition, reflectance values at or above 1000 Hz were affected most by activating the stapedial reflex, even in ears with clinically normal 226 Hz admittance. This is a higher-frequency range than has been reported for acoustically evoked reflex-induced reflectance changes and is consistent with increased middle ear stiffness at rest. Electrically evoked reflexes could be measured more often with the 678 Hz or the broadband probe compared with the 226 Hz probe tone. Although reflex thresholds were lower with the broadband probe compared with the 678 Hz probe in 16 of 24 conditions, this was not a statistically significant finding (Wilcoxon signed-rank test; p = 0.072). CONCLUSIONS: The applications of wideband acoustic immittance measurements (reflectance and reflexes) should also be considered for ears with CIs. Further work is needed to describe changes across time in ears with CIs to more fully understand the reflectance pattern indicating increased middle ear stiffness and to optimize measuring eSRs with a broadband probe.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Scheperle RA, Hajicek JJ. Wideband Acoustic Immittance in Cochlear Implant Recipients: Reflectance and Stapedial Reflexes. Ear Hear. 2020. PMID: 31688195. doi:10.1097/AUD.0000000000000810

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。