磷酸钛氧钾激光焊接喉返神经后喉内收功能研究
本研究在犬半喉模型上比较磷酸钛氧钾(KTP)激光焊接与显微神经缝合修复急性离断喉返神经后的内收功能。术后6个月,激光组喉内收压力比均值为82.4%(95%CI:72.8%-92.0%),缝合组为55.5%(95%CI:49.4%-61.6%),差异为26.9%(95%CI:15.3%-38.5%)。结论认为激光焊接修复喉返神经可获得更强的内收力量。
要点
- KTP激光焊接修复犬离断喉返神经后6个月喉内收压力比缝合组高26.9%。
- 激光焊接与显微缝合组均观察到自发和刺激诱导的声门闭合。
- 激光焊接可作为喉返神经及其他神经吻合的考虑方式。
核心结论
- KTP激光焊接修复急性离断喉返神经后的内收力量优于缝合修复。
- 缝合吻合可能比激光造成更多轴突损伤。
- 更强的声带内收在临床上与更好的误吸防护和嗓音结局相关。
研究设计与样本
- 动物模型研究,犬半喉先进行喉内收功能预处理测试,随后离断喉返神经并分别采用KTP激光焊接(n=8)或显微神经缝合(n=16)修复,6个月后再次测量内收功能并以预处理值的比例表示。
主要发现
- 激光修复组平均喉内收压力比为82.4%(95%CI:72.8%-92.0%)。
- 缝合对照组平均喉内收压力比为55.5%(95%CI:49.4%-61.6%)。
- 两组差异为26.9%(95%CI:15.3%-38.5%)。
- 激光焊接和显微缝合修复组均观察到自发和刺激诱导的声门闭合。
临床怎么用
- 在喉返神经急性离断修复时,可考虑采用KTP激光焊接以改善声带内收功能。
局限性
- 研究为犬动物模型,样本量激光组8、缝合组16,结果外推至人类需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: Recurrent laryngeal nerve (RLN) transection injuries may occur during thyroidectomy and other surgical procedures. Laser nerve welding has been shown to cause less technique-related axonal damage than the traditional suture method. We compared functional adductor results using these two methods of RLN repair. STUDY DESIGN: Animal model. METHODS: Canine hemilarynges underwent pretreatment testing of laryngeal adductor function, followed by RLN transection and repair using potassium titanyl phosphate (KTP) laser welding (n = 8) or microneural suture (n = 16) techniques. Six months later, adductor function was measured again and expressed as a proportion of the pretreatment value. RESULTS: The mean laryngeal adductor pressure ratios were 82.4% (95% confidence interval [CI]: 72.8%-92.0%) for the laser repair group and 55.5% (95% CI: 49.4%-61.6%) for the suture control group, with a difference of 26.9% (95% CI: 15.3%-38.5%). Both spontaneous and stimulated glottic closure was observed in the laser welding and microsuture repair groups. CONCLUSIONS: Laser nerve welding resulted in greater strength of adduction than suture repair of an acutely transected RLN. Suture anastomosis may traumatize more axons than the laser. Stronger vocal fold adduction is associated clinically with better protection from aspiration and improved voice outcomes. KTP laser welding should be considered for anastomosis of the RLN and other nerves. LEVEL OF EVIDENCE: NA Laryngoscope, 130:1764-1769, 2020.
引用
- Bhatt NK, Faddis BT, Paniello RC, et al. Laryngeal adductor function following potassium titanyl phosphate laser welding of the recurrent laryngeal nerve. Laryngoscope. 2019. PMID: 31566750. doi:10.1002/lary.28295
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。