文献速递耳科与耳神经

成人听力损失者畸变产物耳声发射成分的观察

Observations of Distortion Product Otoacoustic Emission Components in Adults With Hearing Loss.
PubMed 文献 · Ear Hear · 2020-01-01

本研究测量45只成人耳(21只听力正常≤15 dB HL,24只轻至重度感音神经性听力损失>15 dB HL)的畸变产物耳声发射(DPOAE),通过扫描初级音提取发生器与反射成分。结果显示听力损失耳DPOAE精细结构减弱或消失,反射成分尤低,发生器成分与听阈显著相关,提示反射成分评估或有助于识别听力损失。

要点

  • 听力损失耳DPOAE精细结构减弱或消失,反射成分常不可记录。
  • 发生器成分与听阈显著相关,反射成分与听阈无显著相关。
  • 多数听力损失耳仅存发生器成分,正常耳多有两成分。

核心结论

  • 听力损失耳反射成分低或不可记录,解释DPOAE精细结构减弱或消失。
  • 发生器成分在听力损失耳也降低,且与听阈显著相关。

研究设计与样本

  • 测量45只成人耳,21只听力正常(≤15 dB HL),24只轻至重度感音神经性听力损失(>15 dB HL)。
  • f2在1500-6000 Hz对数扫描,f2/f1=1.22,两初级音等声级55-75 dB SPL以5 dB步进变化。

主要发现

  • 听力损失耳DPOAE精细结构减弱或消失。
  • 听力损失耳发生器与反射成分均低于正常耳,反射成分尤甚。
  • 发生器成分与听阈显著相关,反射成分与听阈无显著相关。
  • 多数正常耳两成分均存在,仅少数听力损失耳两成分均存在。
  • 两成分均存在时,其关系与有无听力损失无关。

临床怎么用

  • 反射成分在听阈>15 dB HL的耳中多不可测,评估听力损失应结合发生器成分。
  • 可探索刺激频率或长潜伏期瞬态诱发耳声发射等其他反射类型。

局限性

  • 本研究为初步数据,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Distortion product otoacoustic emissions (DPOAEs) measured in the ear canal are composed of OAEs generated by at least two mechanisms coming from different places in the cochlea. Otoacoustic emission (OAE) models hypothesize that reduction of cochlear gain will differentially impact the components. The purpose of the current experiment was to provide preliminary data about DPOAE components in adults with hearing loss in relation to OAE models and explore whether evaluation of the relative amplitudes of generator and reflection components can enhance identification of hearing loss. DESIGN: DPOAEs were measured from 45 adult ears; 21 had normal hearing (≤15 dB HL) and 24 with mild-to-severe sensorineural hearing loss (>15 dB HL). The higher frequency primary (f2) was swept logarithmically between 1500 and 6000 Hz, and f2/f1 was 1.22. The two equal-level primaries varied from 55 to 75 dB SPL in 5 dB steps. The swept primary procedure permitted the measurement of the amplitude and phase of the DPOAE fine structure and the extraction of the two major components (generator and reflection) by varying the predicted delays of the analysis windows. RESULTS: DPOAE fine structure was reduced or absent in ears with hearing loss. DPOAE generator and reflection components were lower in ears with hearing loss than those with normal hearing, especially for the reflection component. Significant correlations were found between the generator component and hearing threshold but not between reflection levels and hearing threshold. Most ears with normal hearing had both components, but only a small number of ears with hearing loss had both components. CONCLUSIONS: The reflection component is not recordable or low in level in ears with hearing loss, explaining the reduced or absent DPOAE fine structure. DPOAE generator components are also lower in level in ears with hearing loss than in ears without hearing loss. In ears that had both measurable generator and reflection components, the relationship between the two did not depend on the presence or absence of hearing loss. Because reflection components are not measurable in many ears with hearing thresholds >15 dB HL, stimuli that evoke other types of reflection emissions, such as stimulus-frequency or long-latency transient-evoked emissions, should be explored in conjunction with DPOAE generator components.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Prieve BA, Thomas L, Long G, et al. Observations of Distortion Product Otoacoustic Emission Components in Adults With Hearing Loss. Ear Hear. 2020. PMID: 31569117. doi:10.1097/AUD.0000000000000792

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。