磁共振成像评估鼻腔喷雾与冲洗装置在鼻窦腔内的分布
该研究利用钆对比剂结合MRI,在7名受试者中评估鼻腔喷雾与盐水冲洗在鼻腔及鼻窦的分布。冲洗组2名健康者信号增强广泛分布于鼻腔和上颌窦;喷雾组5名(含术后及CRS患者)热点集中于鼻内阀、鼻中隔前部、下鼻甲下表面、鼻底和鼻咽,但任何鼻窦均无信号增强。该技术可在无辐射下实现三维时空分布评估。
要点
- 冲洗可广泛分布至鼻腔和上颌窦,喷雾仅分布于鼻腔特定区域。
- 喷雾在未手术或已手术鼻窦中均未检测到信号增强。
- MRI对比剂技术可无辐射评估局部药物递送时空分布。
核心结论
- MRI对比剂技术可表征鼻腔喷雾与冲洗在鼻窦腔内的时空分布。
- 盐水冲洗在健康受试者中信号增强广泛分布于鼻腔和上颌窦。
- 鼻腔喷雾热点分布于鼻内阀、鼻中隔前部、下鼻甲下表面、鼻底和鼻咽,鼻窦无增强。
研究设计与样本
- 7名受试者单侧鼻腔给予含钆对比剂的生理盐水,冲洗组2名健康者,喷雾组5名(2健康、2 FESS术后、1 CRS未手术)。
- 采用MRI评估新信号增强,喷雾组在4分钟内进行连续扫描以评估时间变化。
主要发现
- 冲洗组2名健康者鼻腔和上颌窦信号增强广泛。
- 喷雾组信号增强热点与疾病状态或手术史无关,均位于鼻内阀、鼻中隔前部、下鼻甲下表面、鼻底和鼻咽。
- 喷雾组在未手术或已手术的鼻窦中均未检测到信号增强。
临床怎么用
- 该技术可用于无辐射评估患者个体化三维几何中局部药物递送区域分布。
- 喷雾递送主要覆盖鼻腔特定区域,鼻窦分布有限,临床选择装置时需考虑目标区域。
局限性
- 样本量小(共7名,冲洗组仅2名)。
- 喷雾组仅1名CRS未手术患者,疾病状态代表性有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Optimizing intranasal distribution and retention of nasal sprays is essential in the management of patients with chronic rhinosinusitis (CRS), including those that have had functional endoscopic sinus surgery (FESS). Despite multiple existing distribution studies, there remains a need for a technique that allows regionalization of particle deposition within a patient's unique 3-dimensional (3D) geometry without exposing the patient to radiation. METHODS: Seven participants delivered normal saline containing a gadolinium-based contrast agent (GBCA) by either saline irrigation or nasal sprays on 1 side of the nasal cavity. The saline irrigation group included 2 participants (both healthy) while the nasal spray group included 5 participants (2 healthy, 2 post-FESS patients, 1 CRS patient without any sinus surgery). The distribution of new signal enhancement was assessed on each participant using magnetic resonance imaging (MRI). Serial scans were performed over an interval of 4 minutes in the nasal spray group to assess changes in intranasal distribution over time. RESULTS: Signal enhancement was widespread within the nasal cavities and maxillary sinuses of participants (both healthy) that underwent sinus irrigation. For the nasal spray participants, the hotspots for signal enhancement were similar regardless of disease status or previous history of surgery. These included the internal nasal valve, anterior septum, inferior surface of the inferior turbinate, nasal floor, and nasopharynx. No signal enhancement was detected with nasal sprays in either unoperated or operated paranasal sinuses. CONCLUSION: A technique has been developed using MRI evaluation of radioopaque contrast to characterize the temporospatial distribution of topical drug delivery within the sinonasal cavities.
引用
- Siu J, Johnston JJ, Pontre B, et al. Magnetic resonance imaging evaluation of the distribution of spray and irrigation devices within the sinonasal cavities. Int Forum Allergy Rhinol. 2019. PMID: 31476267. doi:10.1002/alr.22376
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。