量化临床验配助听器的信号修饰范围
研究从三家听力学诊所获取成人感音神经性听力损失患者的匿名助听器验配数据,在实验室匹配助听器上于四种信噪比和三种给声级下录音,用助听器言语质量指数的倒谱相关成分量化信号修饰。结果显示信号修饰随信噪比降低和给声级升高而增加,制造商间差异显著,技术级别无显著影响,同一听力损失下信号修饰范围宽泛。
要点
- 临床验配助听器的信号修饰随信噪比降低和给声级升高而增加。
- 不同制造商对聆听条件的处理存在显著差异,技术级别无显著影响。
- 相同听力损失、同一制造商和聆听条件下,信号修饰值范围宽泛。
核心结论
- 临床验配助听器的信号修饰值可代表当前诊所常见验配情况。
- 信号修饰受信噪比、给声级和制造商影响,技术级别无显著影响。
研究设计与样本
- 从三家听力学诊所获取成人感音神经性听力损失用户的匿名助听器验配数据。
- 匹配实验室助听器按匿名数据编程,在四种信噪比和三种给声级下录音。
- 用助听器言语质量指数的倒谱相关成分量化信号修饰。
主要发现
- 信号修饰随信噪比降低和给声级升高而增加。
- 制造商间差异显著,给声级效应随信噪比和制造商不同而变化。
- 技术级别无显著影响。
- 一家制造商中纯音平均听阈对信号修饰有小效应,听力学图斜率无效应。
- 相同听力损失、同一制造商和聆听条件下信号修饰范围宽泛。
临床怎么用
- 临床验配时应考虑制造商间信号处理差异对聆听条件的影响。
- 同一听力损失下信号修饰变异大,提示需个体体验证。
局限性
- 研究为实验室录音量化,未报告行为学影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Hearing aids provide various signal processing techniques with a range of parameters to improve the listening experience for a hearing-impaired individual. In previous studies, we reported significant differences in signal modification for mild versus strong signal processing in commercially available hearing aids. In this study, the authors extend this work to clinically prescribed hearing aid fittings based on best-practice guidelines. The goals of this project are to determine the range of cumulative signal modification in clinically fit hearing aids across manufacturers and technology levels and the effects of listening conditions including signal to noise ratio (SNR) and presentation level on these signal modifications. DESIGN: We identified a subset of hearing aids that were representative of a typical clinical setting. Deidentified hearing aid fitting data were obtained from three audiology clinics for adult hearing aid users with sensorineural hearing loss for a range of hearing sensitivities. Matching laboratory hearing aids were programmed with the deidentified fitting data. Output from these hearing aids was recorded at four SNRs and three presentation levels. The resulting signal modification was quantified using the cepstral correlation component of the Hearing Aid Speech Quality Index which measures the speech envelope changes in the context of a model of the listener's hearing loss. These metric values represent the hearing aid processed signal as it is heard by the hearing aid user. Audiometric information was used to determine the nature of any possible association with the distribution of signal modification in these clinically fit hearing aids. RESULTS: In general, signal modification increased as SNR decreased and presentation level increased. Differences across manufacturers were significant such that the effect of presentation level varied differently at each SNR, for each manufacturer. This result suggests that there may be variations across manufacturers in processing various listening conditions. There was no significant effect of technology level. There was a small effect of pure-tone average on signal modification for one manufacturer, but no effect of audiogram slope. Finally, there was a broad range of measured signal modification for a given hearing loss, for the same manufacturer and listening condition. CONCLUSIONS: The signal modification values in this study are representative of commonly fit hearing aids in clinics today. The results of this study provide insights into how the range of signal modifications obtained in real clinical fittings compares with a previous study. Future studies will focus on the behavioral implications of signal modifications in clinically fit hearing aids.
引用
- Rallapalli V, Anderson M, Kates J, et al. Quantifying the Range of Signal Modification in Clinically Fit Hearing Aids. Ear Hear. 2020. PMID: 31408045. doi:10.1097/AUD.0000000000000767
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。