文献速递耳科与耳神经

反相刺激提高数字噪声测试敏感性

Improving Sensitivity of the Digits-In-Noise Test Using Antiphasic Stimuli.
PubMed 文献 · Ear Hear · 2020-01-01

本研究纳入成人听力测试者,比较反相与同相数字噪声测试对听力损失的检测敏感性。结果显示反相DIN对对称或非对称感音神经性听力损失及传导性听力损失的敏感性均显著高于同相DIN,且重测信度高,适合作为大规模听力筛查工具。

要点

  • 反相DIN对各类听力损失的检测敏感性显著优于同相DIN。
  • 反相DIN的ROC曲线下面积达0.94,高于同相DIN的0.77。
  • 反相DIN可检测传导性听力损失,弥补既往版本不足。

核心结论

  • 反相数字呈现显著提高了DIN对对称或非对称感音神经性听力损失及传导性听力损失的检测敏感性。

研究设计与样本

  • 横断面研究纳入18至84岁成人,按4频率纯音平均听阈分为正常听力组(n=41)、对称感音神经性听力损失组(n=57)、单侧或非对称感音神经性听力损失组(n=24)及传导性听力损失组(n=23)。
  • 采用重复测量设计比较反相与同相言语接收阈。

主要发现

  • 反相DIN对三种听力损失的敏感性均显著高于同相DIN。
  • 所有测试的重测信度高(组内相关系数r>0.89)。
  • 检测听力损失(>25 dB HL)的ROC曲线下面积反相DIN为0.94,同相DIN为0.77。
  • 校正年龄后,正常听力或对称感音神经性听力损失者的纯音平均听阈与反相DIN的言语接收阈相关性(rpartial[96]=0.69)强于同相DIN(rpartial=0.54)。
  • 正常听力或传导性听力损失者的纯音平均听阈与反相DIN的言语接收阈相关性(rpartial[62]=0.92)强于同相DIN(rpartial[62]=0.64)。

关键数值与推荐

  • 听力损失判定标准为纯音平均听阈>25 dB HL。
  • 传导性听力损失判定需纯音平均听阈>25 dB HL且气骨导差≥20 dB HL(较差耳)。
  • 反相DIN检测听力损失的ROC曲线下面积为0.94,同相DIN为0.77。

临床怎么用

  • 反相DIN可作为基于智能手机的大规模听力筛查首选工具,尤其适用于检测单侧或非对称性感音神经性听力损失及传导性听力损失。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The digits-in-noise test (DIN) has become increasingly popular as a consumer-based method to screen for hearing loss. Current versions of all DINs either test ears monaurally or present identical stimuli binaurally (i.e., diotic noise and speech, NoSo). Unfortunately, presentation of identical stimuli to each ear inhibits detection of unilateral sensorineural hearing loss (SNHL), and neither diotic nor monaural presentation sensitively detects conductive hearing loss (CHL). After an earlier finding of enhanced sensitivity in normally hearing listeners, this study tested the hypothesis that interaural antiphasic digit presentation (NoSπ) would improve sensitivity to hearing loss caused by unilateral or asymmetric SNHL, symmetric SNHL, or CHL. DESIGN: This cross-sectional study recruited adults (18 to 84 years) with various levels of hearing based on a 4-frequency pure-tone average (PTA) at 0.5, 1, 2, and 4 kHz. The study sample was comprised of listeners with normal hearing (n = 41; PTA ≤ 25 dB HL in both ears), symmetric SNHL (n = 57; PTA > 25 dB HL), unilateral or asymmetric SNHL (n = 24; PTA > 25 dB HL in the poorer ear), and CHL (n = 23; PTA > 25 dB HL and PTA air-bone gap ≥ 20 dB HL in the poorer ear). Antiphasic and diotic speech reception thresholds (SRTs) were compared using a repeated-measures design. RESULTS: Antiphasic DIN was significantly more sensitive to all three forms of hearing loss than the diotic DIN. SRT test-retest reliability was high for all tests (intraclass correlation coefficient r > 0.89). Area under the receiver operating characteristics curve for detection of hearing loss (>25 dB HL) was higher for antiphasic DIN (0.94) than for diotic DIN (0.77) presentation. After correcting for age, PTA of listeners with normal hearing or symmetric SNHL was more strongly correlated with antiphasic (rpartial[96] = 0.69) than diotic (rpartial = 0.54) SRTs. Slope of fitted regression lines predicting SRT from PTA was significantly steeper for antiphasic than diotic DIN. For listeners with normal hearing or CHL, antiphasic SRTs were more strongly correlated with PTA (rpartial[62] = 0.92) than diotic SRTs (rpartial[62] = 0.64). Slope of the regression line with PTA was also significantly steeper for antiphasic than diotic DIN. The severity of asymmetric hearing loss (poorer ear PTA) was unrelated to SRT. No effect of self-reported English competence on either antiphasic or diotic DIN among the mixed first-language participants was observed. CONCLUSIONS: Antiphasic digit presentation markedly improved the sensitivity of the DIN test to detect SNHL, either symmetric or asymmetric, while keeping test duration to a minimum by testing binaurally. In addition, the antiphasic DIN was able to detect CHL, a shortcoming of previous monaural or binaurally diotic DIN versions. The antiphasic DIN is thus a powerful tool for population-based screening. This enhanced functionality combined with smartphone delivery could make the antiphasic DIN suitable as a primary screen that is accessible to a large global audience.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. De Sousa KC, Swanepoel W, Moore DR, et al. Improving Sensitivity of the Digits-In-Noise Test Using Antiphasic Stimuli. Ear Hear. 2020. PMID: 31425362. doi:10.1097/AUD.0000000000000775

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。