扁桃体切除术中罕见电外科并发症:国家不良事件报告分析
OBJECTIVES: To identify U.S. Food and Drug Administration (FDA)-reported adverse events related to electrosurgical devices during tonsillectomy and characterize the most common devices and patient/provider sequelae.…
要点
- 设备故障是扁桃体切除术电外科最常见不良事件(202例,31%)。
- 烧伤多发生于口腔(76%),以一度烧伤为主(15%),多保守处理(36%)。
- 术后出血报告173例(26%),其中3例死亡,需警惕。
核心结论
- 扁桃体切除术中多种电外科设备可导致显著的患者/提供者伤害及后遗症。
主要发现
- 设备故障最常见(202例,31%),其次为烧伤(患者187例,占烧伤98%;提供者3例,2%)和术后出血(173例,26%;3例死亡)。
- 烧伤最常使用等离子刀(78例,42%)、单极电刀(48例,25%)和电外科发生器(23例,13%)。
- 烧伤最常发生于口腔(144例,76%),最常见为一度烧伤(28例,15%)。
- 烧伤相关并发症36%保守处理(68例),二次手术罕见(8例,4%);术中火灾报告73例(11%)。
关键数值与推荐
- 设备故障导致17%的发生出现显著手术室延迟或取消(35例)。
临床怎么用
- 外科医生应了解电外科设备相关并发症的性质,以促进安全的围手术期护理并指导术前患者讨论。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To identify U.S. Food and Drug Administration (FDA)-reported adverse events related to electrosurgical devices during tonsillectomy and characterize the most common devices and patient/provider sequelae. STUDY DESIGN: Retrospective analysis of FDA database of device-related adverse events. METHODS: Data were extracted from the OpenFDA database for all adverse events reported for electrosurgical devices used in tonsillectomies from January 2008 to December 2017. Adverse events were classified by device, event type, etiology, complication severity, and patient disposition. RESULTS: Six hundred fifty-two adverse events were identified, with 195 events (30%) leading to known bodily injury to patient/provider. Device failure was the most common adverse event (202 events, 31%), followed by burns in 187 patient (98% of burns) and three provider events (2%). Burn injuries occurred most frequently with coblation devices (78 events, 42% of burns), monopolar electrocautery (48 events, 25%), and electrosurgical generators (23 events, 13%). Burn injuries most commonly occurred in the oral cavity (144 events, 76% of burn events) and were most commonly first-degree (28 events, 15%). Complications related to burns were managed conservatively for 36% of burn events (68 events), and secondary surgery was rarely required (8 events, 4%). Postoperative bleeding (173 events, 26%; 3 deaths) and intraoperative fire (73 events, 11%) were also reported. Device failures caused significant OR delay or cancellation in 17% of occurrences (35 events). CONCLUSION: Numerous complications may occur with various devices used during tonsillectomy and can result in significant patient/provider harm and sequelae. Surgeons must understand the nature of such complications to facilitate safe perioperative care and inform preoperative patient discussions. LEVEL OF EVIDENCE: NA Laryngoscope, 130:1138-1143, 2020.
引用
- Yamasaki A, Bhattacharyya N. Rare electrosurgical complications in tonsillectomy: Analysis of national adverse event reporting. Laryngoscope. 2019. PMID: 31294839. doi:10.1002/lary.28181
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。