文献速递头颈外科

影像引导手术室在头颈外科中的应用价值及对术者表现的影响

The image-guided operating room-Utility and impact on surgeon's performance in the head and neck surgery.
PubMed 文献 · Head Neck · 2019-07-09

本研究评估影像引导手术室中锥形束CT(CBCT)在真实临床条件下的图像质量,并探讨其对手术表现和决策的影响。10例头颈外科患者共28次术中扫描由经验丰富的临床医生进行问卷式图像评估。结果显示CBCT对骨性细节和复杂肿瘤重建的临床效用较好,但对软组织分辨能力有限。

要点

  • CBCT骨性细节中位评分为4分(5分制),图像伪影控制评分为4分。
  • 静脉造影使血管细节评分从1分提升至3分(P<10^-8),感兴趣区CT值为284 HU(SD 47 HU)。
  • 软组织分辨评分为2分,加用碘对比剂无显著改善(P=.2)。

核心结论

  • 影像引导手术室中CBCT的图像质量在骨性细节和头颈复杂肿瘤重建方面表现良好,但对术中软组织 delineation 的获益可能有限。

研究设计与样本

  • 前瞻性研究,纳入10例初始患者,共进行28次术中扫描,采用问卷式图像评估,由经验丰富的头颈临床医生在5点Likert量表(1-5分)上对图像质量和临床效用进行评分。

主要发现

  • 骨性细节中位评分为4分(5分制)。
  • 血管细节评分在使用静脉对比剂后从1分提升至3分(P<10^-8),感兴趣区CT值为284 HU(SD 47 HU)。
  • 图像伪影控制评分为4分。
  • 软组织分辨评分为2分,加用静脉碘对比剂后无显著改善(P=.2)。
  • 术者认为CBCT在评估复杂病例重建后影像时临床效用最高,评分为4分。

临床怎么用

  • 在头颈肿瘤手术中,影像引导手术室的CBCT可用于评估骨性细节和复杂重建效果。
  • 对于术中软组织分辨需求较高的场景,CBCT的增益可能有限,需结合临床判断。

局限性

  • 样本量较小(10例患者,28次扫描),仅用于初步评估。
  • 研究未报告临床结局,需未来研究进一步验证影像引导手术室的价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The image-guided operating room (OR) is an emerging standard for dealing with complex cases in many surgical disciplines including neurosurgery, thoracic surgery, maxillofacial trauma, and orthopedic surgery. Its use in head and neck oncological surgery is not well established. The primary aim of this study was to assess the image quality of cone-beam CT (CBCT) under real clinical conditions. The secondary aim was to assess the effect on surgical performance and decision making. METHODS: Intraoperative 3D imaging was performed using a CBCT capable C-Arm mounted on a multi-axis robot (Siemens Zeego) in the image-guided OR. All patients had immediate preoperative imaging taken with further intraoperative imaging performed as required. Ten initial patients, comprising 28 intraoperative scans, were used for questionnaire-based image reviews conducted with experienced head and neck clinicians. Scans were assessed for aspects of both image quality and clinical utility, on separate 5-point Likert scales (1-5). RESULTS: The median rating for bony detail was 4 out of 5. Vascular detail was increased (P < 10-8 ) from 1 to 3 with the use of IV contrast (region of interest CT# was 284 HU [SD, 47 HU]). Images were rated as 4 for freedom from artifact. Soft tissue definition was 2, with no significant improvement (P = .2) with the addition of IV iodinated contrast. Surgeons rated the greatest clinical utility (4) for the CBCT when assessing postreconstruction imaging of a complex case. CONCLUSIONS: The image quality of CBCT in the image-guided OR is good for bony detail and complex oncological reconstructions in the head and neck setting but probably has limited benefit for intraoperative soft tissue delineation. Future studies must also focus on clinical outcomes to help demonstrate the value of the image-guided OR.

来源:Head Neck,查看原文。版权归原作者所有。

引用

  1. Muhanna N, Douglas CM, Daly MJ, et al. The image-guided operating room-Utility and impact on surgeon's performance in the head and neck surgery. Head Neck. 2019. PMID: 31287216. doi:10.1002/hed.25864

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。