单侧声带运动障碍患者PET-CT高代谢表现的发生率与意义
回顾性队列研究纳入135例单侧声带运动障碍患者,排除因喉肿瘤行影像者后,21例(19%)出现喉部不对称高代谢,对侧13例(12%)均无炎症或肿瘤证据,同侧8例(7%)中2例(25%)需手术活检;
要点
- 单侧声带运动障碍患者中喉部不对称高代谢发生率约19%。
- 对侧高代谢可能为假阳性,同侧高代谢需警惕并评估。
- 注射内移术后近期扫描可现注射侧高代谢,宜注意时机。
核心结论
- 单侧声带运动障碍患者的对侧喉部高代谢可能为假阳性。
- 无近期声带操作的同侧高代谢应尽快诊断评估。
研究设计与样本
- 回顾性队列研究,单中心三级医疗机构。
- 共135例单侧声带运动障碍患者接受PET-CT。
- 排除27例因喉肿瘤行新发或监测影像者。
主要发现
- 不对称喉部高代谢21例(19%),对侧13例(12%),同侧8例(7%)。
- 同侧高代谢8例中2例(25%)后续喉镜检查可疑并手术活检。
- 对侧高代谢患者均无炎症或肿瘤疾病证据。
临床怎么用
- 对无近期声带操作的同侧喉部高代谢应行喉镜及必要活检。
- 对侧高代谢需结合临床,避免过度解读为肿瘤。
- 注射内移术后短期内PET-CT可现注射侧高代谢,解读需考虑时间因素。
局限性
- 回顾性单中心设计。
- 样本量有限。
- 注射后扫描与无异常扫描的时间差异可能影响结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine the incidence and significance of asymmetric hypermetabolic laryngeal findings on positron emission tomography-computed tomography (PET-CT) in patients with unilateral true vocal fold (TVF) motion abnormalities. STUDY DESIGN: Retrospective cohort. SETTING: Single-center tertiary care institution. SUBJECTS AND METHODS: The medical records of patients with unilateral TVF motion abnormalities were reviewed. The incidence of normal and asymmetric hypermetabolic laryngeal findings was calculated in patients who underwent PET-CT and laryngeal examination, operative laryngoscopy with biopsy, or injection medialization laryngoplasty. RESULTS: A total of 135 patients with unilateral TVF motion abnormalities underwent PET-CT. After exclusion of patients who completed new or surveillance imaging for a laryngeal neoplasm (n = 27), asymmetric hypermetabolic findings in the larynx were noted in 21 (19%) cases: 13 (12%) on the contralateral side of the impaired TVF, 8 (7%) on the ipsilateral side. Two (25%) patients with ipsilateral hypermetabolism had concerning subsequent fiberoptic laryngeal examinations prompting operative biopsy. There was no evidence of inflammatory or neoplastic disease in all patients with contralateral hypermetabolic findings. Fifteen patients completed PET-CT scans after injection medialization procedures; 6 (40%) displayed avidity ipsilateral to the side of the injection. The median time from injection to scan was 27 days, as opposed to 193 days in the unremarkable scans (P = .011). CONCLUSION: Contralateral hypermetabolism in patients with unilateral TVF motion abnormalities may represent a false-positive finding. Ipsilateral hypermetabolic uptake without recent fold instrumentation warrants prompt diagnostic evaluation.
引用
- Stanisce L, Renzi T, Paripati N, et al. Incidence and Significance of Hypermetabolic PET-CT Findings in Unilateral TVF Motion Impairment. Otolaryngol Head Neck Surg. 2019. PMID: 31335258. doi:10.1177/0194599819866403
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。