理解可穿戴助听器中个体对助听器信号处理反应的可变性
研究纳入49名54至90岁对称轻中度感音神经性听力损失老年人,随机双盲对比轻度与强信号处理两种助听器验配,每种佩戴约5周后测试噪声下言语识别。结果显示信号处理对言语清晰度的影响取决于年龄、工作记忆容量和听力损失程度,强信号处理下言语识别随年龄增长而下降。
要点
- 强信号处理下噪声下言语识别随年龄增长而下降。
- 工作记忆较低者两种处理下噪声下言语识别均低,工作记忆较高者轻度信号处理下识别更好。
- 听力损失程度与信号处理存在交互作用,但效应较小。
核心结论
- 当以总体信号修改量量化特定助听器信号处理特征的后果时,参与者特征与不同信号修改水平下的言语识别之间存在关系。
研究设计与样本
- 研究为双盲随机对照试验,纳入49名54至90岁对称轻中度感音神经性听力损失老年人,35名参与者两种助听器验配均有有效结局数据。
- 对比两种助听器验配:一种指定为轻度信号处理,一种为强信号处理,差异涉及宽动态范围压缩和频率压缩特征。
- 每位参与者的验配顺序随机分配,每种验配在听者日常环境中佩戴约5周后进行结局测量。
- 基线测量包括完整听力学评估以及工作记忆和频谱与时间分辨率,结局为助听后噪声下言语识别。
主要发现
- 两种助听器验配导致不同的信号修改量,轻度信号处理验配的信号修改显著更少。
- 强信号处理下言语识别随年龄增长而下降。
- 工作记忆与信号处理存在交互作用:工作记忆较低者在两种处理条件下噪声下言语清晰度均低,工作记忆较高者在轻度信号处理验配下噪声下言语清晰度更好。
- 听力损失程度与信号处理存在交互作用,但效应较小。
- 个体频谱和时间分辨率对言语清晰度评分的方差无显著贡献。
局限性
- 研究所用助听器验配仅限于代表临床验配中可能出现的信号修改极端的特定验配参数,未来工作应关注与更多样类型信号处理参数的类似关系。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Previous work has suggested that individual characteristics, including amount of hearing loss, age, and working memory ability, may affect response to hearing aid signal processing. The present study aims to extend work using metrics to quantify cumulative signal modifications under simulated conditions to real hearing aids worn in everyday listening environments. Specifically, the goal was to determine whether individual factors such as working memory, age, and degree of hearing loss play a role in explaining how listeners respond to signal modifications caused by signal processing in real hearing aids, worn in the listener's everyday environment, over a period of time. DESIGN: Participants were older adults (age range 54-90 years) with symmetrical mild-to-moderate sensorineural hearing loss. We contrasted two distinct hearing aid fittings: one designated as mild signal processing and one as strong signal processing. Forty-nine older adults were enrolled in the study and 35 participants had valid outcome data for both hearing aid fittings. The difference between the two settings related to the wide dynamic range compression and frequency compression features. Order of fittings was randomly assigned for each participant. Each fitting was worn in the listener's everyday environments for approximately 5 weeks before outcome measurements. The trial was double blind, with neither the participant nor the tester aware of the specific fitting at the time of the outcome testing. Baseline measures included a full audiometric evaluation as well as working memory and spectral and temporal resolution. The outcome was aided speech recognition in noise. RESULTS: The two hearing aid fittings resulted in different amounts of signal modification, with significantly less modification for the mild signal processing fitting. The effect of signal processing on speech intelligibility depended on an individual's age, working memory capacity, and degree of hearing loss. Speech recognition with the strong signal processing decreased with increasing age. Working memory interacted with signal processing, with individuals with lower working memory demonstrating low speech intelligibility in noise with both processing conditions, and individuals with higher working memory demonstrating better speech intelligibility in noise with the mild signal processing fitting. Amount of hearing loss interacted with signal processing, but the effects were small. Individual spectral and temporal resolution did not contribute significantly to the variance in the speech intelligibility score. CONCLUSIONS: When the consequences of a specific set of hearing aid signal processing characteristics were quantified in terms of overall signal modification, there was a relationship between participant characteristics and recognition of speech at different levels of signal modification. Because the hearing aid fittings used were constrained to specific fitting parameters that represent the extremes of the signal modification that might occur in clinical fittings, future work should focus on similar relationships with more diverse types of signal processing parameters.
引用
- Souza P, Arehart K, Schoof T, et al. Understanding Variability in Individual Response to Hearing Aid Signal Processing in Wearable Hearing Aids. Ear Hear. 2019. PMID: 30998547. doi:10.1097/AUD.0000000000000717