单侧聋伴人工耳蜗植入者在同位与空间分离噪声及言语掩蔽下的定位与言语感知机制
研究纳入8例一侧人工耳蜗、对侧有残余听力的单侧聋者,测试其声源定位与在同位或空间分离的噪声/言语掩蔽下的言语识别,并与年龄匹配的正常听力者比较。结果显示定位改善仅在高频耳间强度差可用时出现,言语识别在双人语噪掩蔽下部分受益。
要点
- 定位改善仅在高频耳间强度差可用时出现,包络或精细结构中的耳间时间差未带来额外获益。
- 双人语噪掩蔽下,8例中7例在目标位于前方、语噪位于声学耳侧时言语识别获人工耳蜗受益。
- 其余条件下人工耳蜗对言语识别的获益很小或无获益。
核心结论
- 对侧有显著残余听力时,人工耳蜗可改善声源定位,但仅限含高频成分的声音且仅基于耳间强度差。
- 言语理解方面,人工耳蜗在言语掩蔽下处于信噪比更优耳时贡献最大。
研究设计与样本
- 研究纳入8例一侧人工耳蜗、对侧声学听力从正常听力至中度感音神经性听力损失的听者。
- 其中5例测试定位准确度,使用强调耳间强度差与包络和/或精细结构中耳间时间差分别贡献的刺激。
- 全部8例测试句子识别,使用同位与空间分离的语音谱高斯噪声和双人语噪。
- 通过扬声器或经耳机以人工耳蜗处理声码器模拟与年龄匹配的正常听力者比较表现。
主要发现
- 定位随人工耳蜗改善,但仅在高频耳间强度差可用时出现。
- 使用真实或声码器模拟人工耳蜗时,刺激包络或精细结构中的耳间时间差均未带来额外获益。
- 双人语噪掩蔽下,8例中7例在目标位于前方、语噪位于声学耳侧时言语识别随人工耳蜗改善,其余情况获益很小或无获益。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN: Eight CI listeners with contralateral acoustic hearing ranging from normal hearing to moderate sensorineural hearing loss were tested. Localization accuracy was measured in five of the listeners using stimuli that emphasized the separate contributions of interaural level differences (ILDs) and interaural time differences (ITD) in the temporal envelope and/or fine structure. Sentence recognition was tested in all eight CI listeners, using collocated and spatially separated speech-shaped Gaussian noise and two-talker babble. Performance was compared with that of age-matched normal-hearing listeners via loudspeakers or via headphones with vocoder simulations of CI processing. RESULTS: Localization improved with the CI but only when high-frequency ILDs were available. Listeners experienced no additional benefit via ITDs in the stimulus envelope or fine structure using real or vocoder-simulated CIs. Speech recognition in two-talker babble improved with a CI in seven of the eight listeners when the target was located at the front and the babble was presented on the side of the acoustic-hearing ear, but otherwise showed little or no benefit of a CI. CONCLUSION: Sound localization can be improved with a CI in cases of significant residual hearing in the contralateral ear, but only for sounds with high-frequency content, and only based on ILDs. In speech understanding, the CI contributed most when it was in the ear with the better signal to noise ratio with a speech masker.
引用
- Dirks C, Nelson PB, Sladen DP, et al. Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant. Ear Hear. 2019. PMID: 30870240. doi:10.1097/AUD.0000000000000708
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。