在3D打印模型中采用新型解剖适配球囊扩张技术治疗声门后部狭窄
本研究在3D打印声门模型上比较传统单球囊扩张与新型泪滴形声门扩张(TSGD)对声带和后连合施加的压力。TSGD将三角形支架(18-32F)置入前声门、球囊扩张器(10-20 mm)置入后声门,共30种组合。TSGD使后连合与声带受力比值优于单纯圆球囊扩张(P=0.0296),当支架与球囊扩张器前后径之和接近声门前后长度时后连合靶向最佳。
要点
- TSGD在3D打印声门模型中使后连合受力达0.0-17.5 N,球囊扩张器为0.0-3.8 N。
- TSGD的后连合与声带受力比值优于单纯圆球囊扩张(P=0.0296)。
- 支架与球囊扩张器前后径之和接近声门前后长度时后连合靶向最佳。
核心结论
- 解剖适配的声门扩张可最大化施加于后连合的扩张力并减少对声带的力,TSGD最小化前声门受力并最大化后声门扩张,该技术可能有助于预防慢性声门后部狭窄相关的喉狭窄。
研究设计与样本
- 在3D打印声门模型上固定压力传感器,比较传统单球囊扩张与新型解剖适配的泪滴形声门扩张(TSGD)施加于声带和后连合的力。
- TSGD将三角形支架(18-32F)置入前声门、球囊扩张器(10-20 mm)置入后声门,共30种独特组合。
主要发现
- 使用球囊扩张器时后连合扩张力范围为0.0-3.8牛顿(N),使用TSGD时为0.0-17.5 N。
- 与单纯圆球囊扩张相比,TSGD技术的后连合与声带受力比值更优(P=0.0296)。
- 当支架与球囊扩张器前后径(AP)之和接近声门前后长度时,后连合靶向最佳。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Posterior glottic stenosis (PGS) often requires a destructive surgical treatment. Early PGS treatment involves glottic dilation to reduce airway constriction associated with chronic PGS. Round laryngeal dilation may not optimize posterior glottic dilation due to the teardrop shape of the glottis and may injure vocal fold tissue. We compared pressure applied to the glottis during traditional single balloon dilation and a novel, anatomically appropriate dilation technique (teardrop-shaped glottic dilation [TSGD]). METHODS: Pressure sensors were affixed at various points on a three-dimensional printed glottic model. The anterior glottis was stented with a triangular stent (18-32F) in combination with balloon dilator (10-20 mm) placed in the posterior glottis (TSGD) in 30 unique combinations. Force applied to the vocal folds (VF) and posterior commissure (PC) during round balloon dilation and TSGD was measured. RESULTS: Dilatory force in the PC ranged from 0.0-3.8 newtons (N) using balloon dilators and 0.0-17.5 N using TSGD. The TSGD technique yielded a superior ratio of force applied to the PC versus VF (P = 0.0296) compared to round balloon dilation alone. Optimal targeting of the PC occurred when the sum of the anteroposterior (AP) dimensions of the stent and balloon dilator approached the AP length of the glottis. CONCLUSION: Use of an anatomically appropriate glottic dilation maximizes expansive force applied to the posterior commissure and decreased force to the vocal folds. This study demonstrates that TSGD minimizes force to the anterior glottis and maximizes dilation of the posterior glottis. This technique may play a role in preventing laryngeal stenosis associated with chronic PGS. LEVEL OF EVIDENCE: NA Laryngoscope, 129:2239-2243, 2019.
引用
- Cates DJ, Magnetta MJ, Smith LJ, et al. Novel, anatomically appropriate balloon dilation technique of the glottis to treat posterior glottic stenosis in a 3D-printed model. Laryngoscope. 2019. PMID: 30776098. doi:10.1002/lary.27524
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。