原发性头颈癌治疗前与治疗中FDG PET-CT的SUV稳定性前瞻性评估
该前瞻性研究评估头颈癌根治性放化疗患者治疗前与治疗中18-氟脱氧葡萄糖(FDG)PET-CT的标准化摄取值(SUV)稳定性。两位观察者勾画原发肿瘤及淋巴结感兴趣体积,在SUV最大值50%、60%、70%、80%、90%阈值下计算重叠指标。结果显示各阈值下重叠指数均低,中心-中心差异随阈值升高而增大,结论为基于SUV阈值定义的亚体积在放化疗期间物理位置不稳定。
要点
- 治疗前与治疗中所有SUV阈值(50%-90%)重叠指数均低。
- 中心-中心差异进一步证实所有FDG阈值体积在治疗期间不稳定。
- p16阳性与阴性肿瘤间SUV阈值稳定性无差异。
核心结论
- 基于FDG PET-CT SUV阈值技术定义的头颈癌亚体积在放化疗期间物理位置不稳定。
研究设计与样本
- 前瞻性研究,纳入接受根治性放化疗的原发性头颈癌患者,由两位独立观察者在治疗前和治疗中PET-CT上勾画原发肿瘤及淋巴结感兴趣体积。
主要发现
- 50%、60%、70%、80%、90% SUV阈值下平均DICE分别为0.53、0.48、0.41、0.28、0.12。
- 50%、60%、70%、80%、90% SUV阈值下平均重叠分数分别为0.71、0.65、0.58、0.43、0.2。
- 上述SUV亚体积的中心-中心差异分别为7.8、8.2、8.6、9.5、11.2 mm。
- p16阳性与阴性肿瘤间未观察到SUV阈值稳定性差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate standardized uptake value (SUV) stability on pretreatment and intratreatment 18-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) in patients undergoing definitive CRT for head and neck cancer (HNC). METHODS: Primary tumor and nodal volumes of interest (VOIs) from HNC patients were contoured on the pretreatment and intratreatment PET-CT by two independent observers. SUV stability was measured with intersection calculations (DICE, overlap fraction, center to center) between the VOIs at threshold levels of 50%, 60%, 70%, 80%, and 90% of the SUV maximum. RESULTS: The mean calculated DICE of the 50%, 60%, 70%, 80%, 90% SUV threshold was 0.53, 0.48, 0.41, 0.28, and 0.12, respectively. The mean calculated overlap fraction was 0.71, 0.65, 0.58, 0.43, and 0.2, respectively. Center-center difference demonstrates spatial variability of 7.8, 8.2, 8.6, 9.5, and 11.2 mm for these SUV subvolumes of interest. CONCLUSIONS: HNC subvolumes defined by SUV thresholding technique in FDG PET-CT imaging do not remain physically stable during (chemo)RT. HIGHLIGHTS: All pretreatment and intratreatment SUV thresholds (50%-90%) overlap indexes are low during the course of (chemo)radiation. Pretreatment and intratreatment center to center variation further corroborates that all FDG threshold volumes do not remain stable during treatment. No difference in SUV threshold stability was seen between p16 positive and negative tumors.
引用
- Mendez LC, Conrad T, Lee J, et al. Prospective evaluation of pretreatment and intratreatment FDG PET-CT SUV stability in primary head and neck cancer. Head Neck. 2019. PMID: 30688385. doi:10.1002/hed.25624
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。