甲状腺球蛋白洗脱液检测可提高甲状腺乳头状癌转移性囊性淋巴结的检出率
该回顾性研究纳入138例甲状腺癌患者,其中92例(66.7%)接受手术,比较细针穿刺细胞学与细针穿刺甲状腺球蛋白洗脱液检测对转移性颈部淋巴结的诊断效能。细针穿刺甲状腺球蛋白洗脱液检测灵敏度95.8%、特异度90.5%、阴性预测值86.4%,联合细胞学检测囊性/富血供淋巴结灵敏度达98.2%、特异度100.0%、阴性预测值95.0%。
要点
- 细针穿刺甲状腺球蛋白洗脱液检测灵敏度95.8%,高于细胞学单独检测的80.0%。
- 联合检测囊性/富血供淋巴结灵敏度98.2%、特异度100.0%、阴性预测值95.0%。
- 14枚细胞学假阴性恶性淋巴结均显示甲状腺球蛋白洗脱液升高,其中10枚(71.4%)为囊性。
核心结论
- 细针穿刺甲状腺球蛋白洗脱液检测可提高复发性甲状腺癌转移性淋巴结的诊断准确性,在细胞学假阴性的囊性或富血供淋巴结中可能具有特殊诊断价值。
研究设计与样本
- 回顾性研究,基于前瞻性收集的数据库,纳入138例甲状腺癌患者,其中92例(66.7%)接受手术,由学术机构一位外科医生行选择性颈淋巴结清扫,细针穿刺细胞学与细针穿刺甲状腺球蛋白洗脱液检测同时进行,结果与最终手术病理对照。
主要发现
- 细针穿刺细胞学单独检测灵敏度80.0%、特异度100.0%、阴性预测值60.0%。
- 细针穿刺甲状腺球蛋白洗脱液检测灵敏度95.8%、特异度90.5%、阴性预测值86.4%。
- 细胞学联合甲状腺球蛋白洗脱液检测囊性/富血供淋巴结灵敏度98.2%、特异度100.00%、阴性预测值95.0%。
- 14枚细胞学假阴性恶性颈部淋巴结均显示甲状腺球蛋白洗脱液升高,其中10枚(71.4%)为囊性,4枚超声示富血供。
临床怎么用
- 作者认为细针穿刺甲状腺球蛋白洗脱液检测可提高复发性甲状腺癌转移性淋巴结的诊断准确性,在囊性或富血供淋巴结中可能具有特殊诊断重要性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fine-needle aspiration (FNA) cytology has been the standard of care in the workup of cervical lymph nodes (LNs) in patients with recurrent papillary thyroid cancer (PTC) and suspicious cervical LNs. Recently, FNA thyroglobulin (TG) washout measurement has been proposed as an adjunct in the management of these patients. We hypothesize that using FNA-TG washout for suspicious cervical LNs would increase the accuracy of diagnosing metastatic disease especially in cystic and highly vascular cervical LN in patients with recurrent PTC. METHODS: This is a retrospective study of a prospectively collected database for patients with thyroid cancer who underwent preoperative FNA followed by selective neck dissection by one surgeon at an academic institution. FNA-cytology and FNA-TG washout were performed simultaneously. A total of 138 patients were included in our study, of which 92 (66.7%) had undergone surgical intervention. Results of both methods were then correlated with the final surgical pathology. RESULTS: FNA-cytology alone showed a sensitivity of 80.0%, specificity of 100.0% with a negative predictive value (NPV) of 60.0%. By contrast, FNA-TG washout had a sensitivity of 95.8%, specificity of 90.5% with a NPV of 86.4%. Combination of the FNA-cytology with FNA-TG washout of cystic/highly vascular LN increased the accuracy of diagnosis with a sensitivity of 98.2%, specificity of 100.00% with a NPV of 95.0%. All 14 malignant cervical LNs with false-negative FNA-cytology showed elevated FNA-TG washout, 10 (71.4%) of which were cystic in nature and 4 were highly vascular on ultrasonography. CONCLUSION: FNA-TG washout increases the diagnostic accuracy in detecting metastatic disease in patients with recurrent thyroid cancer. FNA-TG washout may be of special diagnostic importance in cystic or highly vascular LNs, which might have falsely negative cytology. LEVEL OF EVIDENCE: 2B.
引用
- Khadra H, Mohamed H, Al-Qurayshi Z, et al. Superior detection of metastatic cystic lymphadenopathy in patients with papillary thyroid cancer by utilization of thyroglobulin washout. Head Neck. 2018. PMID: 30536535. doi:10.1002/hed.25488
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。