根治性调强放疗治疗头颈部鳞状细胞癌的失败模式:基于焦点体积与剂量学方法
111例局部晚期头颈部鳞状细胞癌患者接受调强放疗联合同步化疗,中位随访20个月,3年总生存率和局部区域控制率分别为70.6%和48.9%。39例失败患者中,采用焦点与剂量学方法分类,A型失败占69.2%,B、C、D、E型分别占7.6%、5.1%、12.8%、5.1%。作者认为多数复发为高剂量失败,提示内在放射抵抗,少数失败可能可预防并需修改现有IMRT工作流程。
要点
- 中位随访20个月,3年总生存率70.6%,局部区域控制率48.9%。
- 39例失败中A型(高剂量失败)占69.2%,提示内在放射抵抗。
- 少数失败为潜在可预防,需修改现有IMRT工作流程。
核心结论
- 当前分类下多数复发为高剂量失败,提示内在放射抵抗;少数失败可能可预防并需修改现有IMRT工作流程。
研究设计与样本
- 研究纳入111例接受调强放疗联合同步化疗的局部晚期头颈部鳞状细胞癌患者,对记录到失败的患者采用焦点与剂量学方法评估复发体积。
主要发现
- 中位随访20个月(范围0-39个月),中位局部区域控制时间为30个月(范围24.8-34.5个月)。
- 3年总生存率为70.6%,3年局部区域控制率为48.9%。
- 39例失败中,A型占69.2%,B型占7.6%,C型占5.1%,D型占12.8%,E型占5.1%。
临床怎么用
- 作者认为多数复发为高剂量失败,提示内在放射抵抗;少数失败可能可预防,需修改现有IMRT工作流程。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Labeling locoregional failures in head and neck cancer (HNC) as "local" and "regional" becomes incomplete when treating with intensity modulated radiotherapy (IMRT). Target delineation and delivery errors, dose in-homogeneity complicate the assessment of failures. A combination of focal point and dosimetric method might attempt at simplifying failure analysis. METHODS: One hundred eleven patients with locally advanced HNC treated with chemoradiation using IMRT were enrolled. Patients with documented failure had their recurrence volume assessed using focal point and dosimetric method. RESULTS: With a median follow-up of 20 (range 0-39) months and median locoregional control (LRC) of 30 (range 24.8-34.5) months, the patients had a 3-year overall survival and LRC of 70.6% and 48.9%, respectively. Of 39 failures, there were 69.2%, 7.6%, 5.1%, 12.8%, and 5.1% type A, B, C, D, and E, respectively using the focal point and dosimetric method. CONCLUSION: With the current classification, majority of the recurrences were high dose failures suggesting inherent radioresistance. While minority of failures were potentially preventable and needed modifying existing IMRT workflow.
引用
- Tandon S, Gairola M, Ahlawat P, et al. Failure patterns of head and neck squamous cell carcinoma treated with radical radiotherapy by intensity modulated radiotherapy technique using focal volume and dosimetric method. Head Neck. 2018. PMID: 30582238. doi:10.1002/hed.25586
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。