经鼓室内侧壁后上部最小剂量钆喷酸葡胺给药与hT2W-3D-FLAIR序列检测内淋巴积水的优化

[Optimization of delivering minimum Gd-DTPA at the posterior upper point on tympanic medial wall and hT2W-3D-FLAIR sequence for detecting endolymphatic hydrops].
PubMed 文献 · Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi · 2018-01-01

2017年6—12月纳入13例外周性眩晕患者,经鼓膜穿孔向鼓室内侧壁后上部投放0.10~0.20 ml不同稀释度钆喷酸葡胺,用3T MRI联合hT2W-3D-FLAIR序列于8、24 h检测内淋巴积水;0.10 ml、20倍稀释(总剂量5 μmol)配合8 min 35 s扫描为临床可行方案。

要点

  • 0.15~0.20 ml、10倍稀释Gd-DTPA靶向投放后内耳摄取有效且信噪比高。
  • 0.10 ml、20倍稀释Gd-DTPA(总剂量5 μmol)即可有效显示内淋巴积水,个体差异小。
  • 8 min 35 s与15 min 11 s扫描时间的图像质量无明显差异。

核心结论

  • 经鼓室内侧壁后上部靶向投放0.10 ml、20倍稀释的Gd-DTPA(双耳总剂量5 μmol),结合8 min 35 s的hT2W-3D-FLAIR序列行内耳3T MRI,是临床行之有效的检测内淋巴积水方法,并降低对MRI硬件的要求。

研究设计与样本

  • 2017年6—12月纳入就诊于解放军海军军医大学第一附属医院耳鼻咽喉头颈外科的13例外周性眩晕患者。
  • 用软头鼓室吸引喷药针经预先形成的鼓膜穿孔将0.10~0.20 ml不同稀释度(10、20、40倍)的Gd-DTPA注射到鼓室内侧壁后上部。
  • 分别于8、24 h后用3T Skyra磁共振仪和20通道Tim 4G头/颈线圈行内耳MRI,采用hT2W-3D-FLAIR序列检测内耳钆增强信号及可能存在的内淋巴积水。
  • 与每板层数60和104对应的扫描时间分别为8 min 35 s和15 min 11 s,用SPSS 21.0软件进行统计分析。

主要发现

  • 向鼓室内侧壁后上部靶向投放0.15~0.20 ml、10倍稀释的Gd-DTPA,内耳可产生有效摄取,MRI信噪比很高。
  • 8 h后耳蜗钩端、第一回的鼓阶与前庭阶以及前庭外淋巴腔有显著摄取,所有内淋巴腔均无摄取;24 h后耳蜗各回及前庭外淋巴腔信号均匀。
  • 0.10 ml、40倍稀释的Gd-DTPA内耳摄取存在较大个体差异;0.10、0.15、0.20 ml、20倍稀释者内耳均有效摄取,显示内淋巴积水图像清晰,个体差异很小。
  • 投放0.15 ml者与0.10 ml者的内耳信号强度,除0.15 ml组半规管灰度值在8 h与24 h之间差异有统计学意义(190.00±53.95比165.50±42.13,t=2.61,P<0.05)外,其他差异均无统计学意义。
  • 8 min 35 s与15 min 11 s扫描时间的图像质量无明显差异;7耳存在不同程度耳蜗积水,11耳存在不同程度前庭积水,同时出现耳蜗和前庭积水者4耳;3例临床确诊梅尼埃病者均有耳蜗积水,其中2例合并前庭积水;2例疑似梅尼埃病者和1例疑似上半规管裂综合征者未见内淋巴积水。

关键数值与推荐

  • 推荐靶向投放0.10 ml、20倍稀释的Gd-DTPA(双耳总剂量5 μmol)至鼓室内侧壁后上部。
  • 推荐结合8 min 35 s扫描时间的hT2W-3D-FLAIR序列行内耳3T MRI。
  • 0.15 ml组半规管灰度值8 h与24 h比较为190.00±53.95比165.50±42.13(t=2.61,P<0.05)。

临床怎么用

  • 作者认为经鼓室内侧壁后上部靶向投放0.10 ml、20倍稀释Gd-DTPA结合8 min 35 s的hT2W-3D-FLAIR序列是临床行之有效的检测内淋巴积水方法,可降低对MRI硬件的要求。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To optimize delivery of gadolinium-diethylenetriamine pentaacetic acid(Gd-DTPA) at the posterior upper point on tympanic medial wall and heavily T2-weighted 3-dimensional fluid-attenuated inversion recovery (hT2W-3D-FLAIR) sequence, and to implement the technique of detecting endolymphatic hydrops using gadolinium-enhancement MRI. Methods: Thirteen patients with periphery vertigo, who visited Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Changhai Hospital during June and December of 2017, were enrolled in the study.0.10-0.20 ml of Gd-DTPA in various dilutions (10, 20, and 40-fold) were delivered at the posterior upper point on tympanic medial wall using a soft-tipped tympanic suction and drug-spraying needle through an artificially perforated tympanic membrane. Inner ear MRI was performed at 8, 24 h after Gd-DTPA administration using a 3T MR machine in combination with a 20-channel Tim 4G head/neck coil and the sequence of hT2W-3D-FLAIR to detect the gadolinium-enhancement signal within the inner ear and possible endolymphatic hydrops. The scanning time was either 8 min 35 s or 15 min 11 s. Results: Efficient inner ear uptake of Gd-DTPA was detected and induced high signal to noise ratio of MRI in patients receiving targeted delivery of 0.15-0.20 ml of 10-fold diluted contrast agent at the posterior upper point on tympanic medial wall. At 8 h after delivery, significant uptake was detected in the scala tympani and vestibuli of hook region and basal turn of the cochlea, and perilymhatic compartment of the vestibule. At 24 h after delivery, the distribution of Gd-DTPA became homogenous in each turn of the cochlea and perilymphatic compartment of the vestibule. However, obvious individual variance existed in the inner ear uptake when 0.10 ml of 40-fold diluted Gd-DTPA was delivered. Efficient inner ear uptake and high quality images that generated in patients receiving 0.10, 0.15, and 0.20 ml of 20-fold Gd-DTPA demonstrated endolymphatic hydrops with minor individual variance. There was insignificant difference in the enhancement signal of inner ear between 0.15 and 0.10 ml groups when Gd-DTPA was diluted at 20-fold except for the signal of semicircular canal of 0.15 ml group (190.00±53.95 vs 165.50±42.13, t=2.61, P<0.05). There was insignificant difference in the image quality between 8 min 35 s and 15 min 11 s canning time. Various degrees of endolymphatic hydrops were detected in 7 cochleae and 11 vestibule, and both simultaneous cochlear and vestibular endolymphatic hydrops were detected in 4 ears. Cochlear endolymphatic hydrops was detected in all the 3 patients with definite Meniere's disease, and 2 of them had combined cochlear and vestibular endolymphatic hydrops. Endolymphatic hydrops was not detected in patients with possible Meniere's disease nor with symptoms of superior semicircular canal dehiscence. Conclusion: Targeted delivery of 0.10 ml with 20-fold diluted Gd-DTPA (total dosage of 5 μmol) at the posterior upper point on tympanic medial wall in combination with 8 min 35 s scanning time hT2W-3D-FLAIR sequence for inner ear MRI in a 3T MR machine is a clinically practical method to detect endolymphatic hydrops, and reduce the requirement for MRI hardware. 目的: 探讨优化用于检测内淋巴积水的钆增强MRI技术。 方法: 2017年6—12月,就诊于解放军海军军医大学第一附属医院耳鼻咽喉头颈外科的13例外周性眩晕患者纳入研究。用软头鼓室吸引喷药针将0.10~0.20 ml不同稀释度(10、20、40倍)的钆喷酸葡胺(gadolinium-diethylenetriamine pentaacetic acid,Gd-DTPA)注射液经预先形成的鼓膜穿孔注射到鼓室内侧壁后上部;分别于8、24 h后用3T Skyra磁共振仪和20通道Tim 4G头/颈线圈行内耳MRI,用重T2加权三维液体衰减反转恢复(heavily T2-weighted 3-dimensional fluid-attenuated inversion recovery,hT2W-3D-FLAIR)序列检测内耳钆增强信号及可能存在的内淋巴积水病变,与每板层数60和104对应的扫描时间分别为8 min 35 s和15 min 11 s。观察不同药物剂量、稀释度及扫描时间对检测内淋巴积水的影响。用SPSS 21.0软件进行统计分析。 结果: 向患者鼓室内侧壁后上部靶向投放0.15~0.20 ml、10倍稀释的Gd-DTPA,内耳可产生有效的摄取,MRI的信噪比很高。8 h后耳蜗钩端、第一回的鼓阶与前庭阶以及前庭外淋巴腔有显著摄取,所有内淋巴腔均无摄取;24 h后耳蜗各回及前庭外淋巴腔的信号均匀。对于0.10 ml、40倍稀释的Gd-DTPA,内耳摄取存在较大个体差异。投放体积0.10、0.15、0.20 ml、20倍稀释的Gd-DTPA,内耳均产生了有效的摄取,显示内淋巴积水图像清晰,个体差异很小;其中投放0.15 ml者与0.10 ml者的内耳信号强度,除了0.15 ml组半规管的灰度值在8 h与24 h之间差异有统计学意义(190.00±53.95比165.50±42.13,t=2.61,P<0.05)外,其他差异均无统计学意义。采用8 min 35 s扫描时间与15 min 11 s扫描时间的图像质量无明显差异。7耳存在不同程度的耳蜗积水,11耳存在不同程度的前庭积水,同时出现耳蜗和前庭积水者4耳;3例临床确诊梅尼埃病者均有耳蜗积水,其中2例合并前庭积水;2例疑似梅尼埃病者和1例疑似上半规管裂综合征者未见内淋巴积水。 结论: 经鼓室内侧壁后上部靶向投放0.10 ml、20倍稀释的Gd-DTPA(双耳总剂量5 μmol),结合8 min 35 s的hT2W-3D-FLAIR序列进行内耳3T MRI,是一种临床行之有效的检测内淋巴积水的方法。.

来源:Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Zou J, Wang Z, Chen YK, et al. [Optimization of delivering minimum Gd-DTPA at the posterior upper point on tympanic medial wall and hT2W-3D-FLAIR sequence for detecting endolymphatic hydrops]. Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2018. PMID: 30585006. doi:10.3760/cma.j.issn.1673-0860.2018.12.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。