文献速递耳科与耳神经

语境因素对噪声中言语评分影响的实验室评估:对生态瞬时评估的启示

A Laboratory Evaluation of Contextual Factors Affecting Ratings of Speech in Noise: Implications for Ecological Momentary Assessment.
PubMed 文献 · Ear Hear · 2019-01-01

本研究在实验室控制条件下,纳入18名感音神经性听力损失成人佩戴助听器,考察声学、评分时机和任务变量对主观评分的影响。结果显示,响度、噪声感和可懂度评分随输入级和信噪比变化而可预测地改变,评分时机在最高呈现级下影响噪声感评分,次要任务无显著影响。

要点

  • 可懂度评分随输入级增加而升高,噪声感评分在较差信噪比下升高,响度评分随输入级增加而升高。
  • 在80 dB SPL最高呈现级下,聆听时给出的噪声感评分高于聆听后(p < 0.05)。
  • 次要非听觉任务的存在或关注对质量评分无显著影响(p > 0.1)。

核心结论

  • 组平均听者对响度、噪声感和可懂度的评分随噪声中言语刺激的级和信噪比改变而以可预测方式变化。
  • 有弱证据支持评分时机(声音暴露期间或之后)在某些条件下可影响噪声感评分,但无证据支持时机影响其他质量评分。
  • 无证据支持此处所用类型的次要非听觉任务的存在或关注会影响质量评分。

研究设计与样本

  • 实验室控制条件下研究,18名年龄21至85岁(M = 51.4)的感音神经性听力损失成人佩戴助听器。
  • 噪声中句子以3个总级(50、65、80 dB SPL)和3个信噪比(0、+5、+10 dB SNR)呈现。
  • 听者在操纵时机和任务关注的四种实验条件下对三个音质维度(可懂度、噪声感、响度)进行评分。

主要发现

  • 可懂度评分随输入级增加而升高(p < 0.05)。
  • 噪声感评分在较差信噪比下升高(p < 0.05)。
  • 响度评分随输入级增加而升高(p < 0.05)。
  • 在最高呈现级80 dB SPL下评分时机有显著影响:参与者聆听信号时给出的噪声感评分高于聆听后(p < 0.05)。
  • 次要任务的存在对评分无显著影响(p > 0.1)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: As hearing aid outcome measures move from retrospective to momentary assessments, it is important to understand how contextual factors influence subjective ratings. Under laboratory-controlled conditions, we examined whether subjective ratings changed as a function of acoustics, response timing, and task variables. DESIGN: Eighteen adults (age 21 to 85 years; M = 51.4) with sensorineural hearing loss were fitted with hearing aids. Sentences in noise were presented at 3 overall levels (50, 65, and 80 dB SPL) and 3 signal to noise ratios (0, +5, and +10 dB signal to noise ratio [SNR]). Listeners rated three sound quality dimensions (intelligibility, noisiness, and loudness) under four experimental conditions that manipulated timing and task focus. RESULTS: The quality ratings changed as the acoustics changed: intelligibility ratings increased with input level (p < 0.05); noisiness ratings increased at poorer SNRs (p < 0.05); and loudness ratings increased as input level increased (p < 0.05). Timing of rating was significant at the highest presentation level (80 dB SPL): Participants gave higher noise ratings while listening to the signal than afterward (p < 0.05). Presence of a secondary task had no significant effect on ratings (p > 0.1). CONCLUSIONS: The findings of this laboratory study provide evidence to support the conclusion that group-mean listener ratings of loudness, noisiness, and intelligibility change in predictable ways as level and SNR of the speech in noise stimulus are altered. They also provide weak evidence to support the conclusion that timing of the ratings (during or immediately after sound exposure) can affect noisiness ratings under certain conditions, but no evidence to support the conclusion that timing affects other quality ratings. There is also no evidence to support the conclusion that quality ratings are influenced by the presence of, or focus on, a secondary nonauditory task of the type used here.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Jenstad LM, Gillen L, Singh G, et al. A Laboratory Evaluation of Contextual Factors Affecting Ratings of Speech in Noise: Implications for Ecological Momentary Assessment. Ear Hear. 2019. PMID: 30557223. doi:10.1097/AUD.0000000000000686

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。