文献速递耳科与耳神经

耳蜗植入者如何应对不确定性:词汇加工动态对非规范输入的差异

How Do You Deal With Uncertainty? Cochlear Implant Users Differ in the Dynamics of Lexical Processing of Noncanonical Inputs.
PubMed 文献 · Ear Hear · 2019-01-01

研究让44名语后聋成人耳蜗植入者(23名仅电刺激,21名电刺激加助听器)和28名年龄匹配的年龄典型听力(ATH)对照者听正确发音、首音误发或尾音误发的词并选图,同时追踪眼动。三组均能准确识别目标词,但耳蜗植入者对误发词的正确率下降更大;其注视动态更慢且承诺更弱,但前900毫秒内受误发干扰更小;耳蜗植入者中注视动态可预测言语感知结局。

要点

  • 语后聋成人耳蜗植入者与年龄典型听力者一样进行增量式言语加工。
  • 耳蜗植入者对目标词的注视承诺更慢、更弱,但对误发词的干扰更不敏感。
  • 耳蜗植入者中更快的注视模式与更好的言语感知结局相关。

核心结论

  • 语后聋成人耳蜗植入者以增量方式加工言语,但比年龄典型听力者更慢且更弱地承诺于单一选项,这可能使其更灵活地应对误发。

研究设计与样本

  • 研究纳入44名语后聋成人耳蜗植入者,分为两组:23名使用标准仅电刺激配置,21名在耳蜗植入基础上补充助听器。
  • 纳入28名年龄匹配的年龄典型听力(ATH)对照者。
  • 受试者听正确发音词、首音误发词或尾音误发词,并从含目标及三个无关物品的屏幕中选对应图片,同时追踪注视作为识别目标时间进程的指标。

主要发现

  • 三组均能准确识别目标词,但均对误发形式表现出小幅正确率下降,两种耳蜗植入者的下降更大。
  • 首音误发延迟了对目标的初始注视,但试验结束前对目标的注视部分恢复;尾音误发早期无效应,但后期抑制注视。
  • 两种耳蜗植入者均比ATH对照者更慢且未完全承诺于目标。
  • 在加工前900毫秒内,两种耳蜗植入者受误发形式的干扰均小于ATH听者。
  • 在耳蜗植入者中,注视动态可预测言语感知结局,且独立于该任务正确率;具有更接近ATH听者快速注视模式的耳蜗植入者结局更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Work in normal-hearing (NH) adults suggests that spoken language processing involves coping with ambiguity. Even a clearly spoken word contains brief periods of ambiguity as it unfolds over time, and early portions will not be sufficient to uniquely identify the word. However, beyond this temporary ambiguity, NH listeners must also cope with the loss of information due to reduced forms, dialect, and other factors. A recent study suggests that NH listeners may adapt to increased ambiguity by changing the dynamics of how they commit to candidates at a lexical level. Cochlear implant (CI) users must also frequently deal with highly degraded input, in which there is less information available in the input to recover a target word. The authors asked here whether their frequent experience with this leads to lexical dynamics that are better suited for coping with uncertainty. DESIGN: Listeners heard words either correctly pronounced (dog) or mispronounced at onset (gog) or offset (dob). Listeners selected the corresponding picture from a screen containing pictures of the target and three unrelated items. While they did this, fixations to each object were tracked as a measure of the time course of identifying the target. The authors tested 44 postlingually deafened adult CI users in 2 groups (23 used standard electric only configurations, and 21 supplemented the CI with a hearing aid), along with 28 age-matched age-typical hearing (ATH) controls. RESULTS: All three groups recognized the target word accurately, though each showed a small decrement for mispronounced forms (larger in both types of CI users). Analysis of fixations showed a close time locking to the timing of the mispronunciation. Onset mispronunciations delayed initial fixations to the target, but fixations to the target showed partial recovery by the end of the trial. Offset mispronunciations showed no effect early, but suppressed looking later. This pattern was attested in all three groups, though both types of CI users were slower and did not commit fully to the target. When the authors quantified the degree of disruption (by the mispronounced forms), they found that both groups of CI users showed less disruption than ATH listeners during the first 900 msec of processing. Finally, an individual differences analysis showed that within the CI users, the dynamics of fixations predicted speech perception outcomes over and above accuracy in this task and that CI users with the more rapid fixation patterns of ATH listeners showed better outcomes. CONCLUSIONS: Postlingually deafened CI users process speech incrementally (as do ATH listeners), though they commit more slowly and less strongly to a single item than do ATH listeners. This may allow them to cope more flexible with mispronunciations.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. McMurray B, Ellis TP, Apfelbaum KS, et al. How Do You Deal With Uncertainty? Cochlear Implant Users Differ in the Dynamics of Lexical Processing of Noncanonical Inputs. Ear Hear. 2019. PMID: 30531260. doi:10.1097/AUD.0000000000000681

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。