宽带接触式助听器CAM2验配的增益与主观效果
研究纳入78例(149耳)轻至中重度感音神经性听力损失患者,在八个临床中心验配光驱动接触式助听器(Earlens系统),采用CAM2为经验用户预设增益后按需调整。结果显示6-10 kHz调整后增益平均45 dB,功能增益平均39 dB;助听器获益简表在背景噪声、混响和沟通便利性亚量表较无辅助聆听平均提升28-32个百分点。
要点
- CAM2预设6-10 kHz增益平均53 dB,调整后降至平均45 dB。
- 6-10 kHz实测功能增益平均39 dB,范围11-62 dB。
- 较无辅助聆听,背景噪声等亚量表平均提升28-32个百分点。
核心结论
- 参与者能够使用Earlens系统并获得主观获益,多数人偏好略低于CAM2经验用户预设的6-10 kHz增益。
研究设计与样本
- 共78例(149耳)轻至中重度感音神经性听力损失患者,在八个临床中心完成两项研究之一。
- 参与者验配光驱动接触式助听器(Earlens系统),采用CAM2为经验用户预设增益,按需调整并长期佩戴。
主要发现
- CAM2预设的6-10 kHz低水平插入增益平均53 dB,范围26-86 dB。
- 调整后6-10 kHz增益平均45 dB,范围16-86 dB。
- 6-10 kHz实测功能增益平均39 dB,范围11-62 dB。
- 助听器获益简表显示,背景噪声、混响和沟通便利性亚量表较无辅助聆听平均提升28-32个百分点。
- 与参与者自有的声学助听器相比,Earlens在沟通便利性和厌恶感亚量表上提升6-7个百分点。
临床怎么用
- 对轻至中重度感音神经性听力损失患者,可考虑使用Earlens系统提供6-10 kHz扩展高频放大。
- 按CAM2为经验用户预设增益后,应根据患者响度与舒适度偏好及功能增益测量进行个体化调整。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The objective of this study was to test the ability to achieve, maintain, and subjectively benefit from extended high-frequency amplification in a real-world use scenario, with a device that restores audibility for frequencies up to 10 kHz. DESIGN: A total of 78 participants (149 ears) with mild to moderately-severe sensorineural hearing loss completed one of two studies conducted across eight clinical sites. Participants were fitted with a light-driven contact hearing aid (the Earlens system) that directly drives the tympanic membrane, allowing extended high-frequency output and amplification with minimal acoustic feedback. Cambridge Method for Loudness Equalization 2 - High Frequency (CAM2)-prescribed gains for experienced users were used for initial fitting, and adjustments were made when required according to participant preferences for loudness and comfort or when measures of functional gain (FG) indicated that more or less gain was needed. Participants wore the devices for an extended period. Prescribed versus adjusted output and gain, frequency-specific FG, and self-perceived benefit assessed with the Abbreviated Profile of Hearing Aid Benefit, and a custom questionnaire were documented. Self-perceived benefit results were compared with those for unaided listening and to ratings with participants' own acoustic hearing aids. RESULTS: The prescribed low-level insertion gain from 6 to 10 kHz averaged 53 dB across all ears, with a range from 26 to 86 dB. After adjustment, the gain from 6 to 10 kHz decreased to an average of 45 dB with a range from 16 to 86 dB. Measured FG averaged 39 dB from 6 to 10 kHz with a range from 11 to 62 dB. Abbreviated Profile of Hearing Aid Benefit results revealed a significant improvement in communication relative to unaided listening, averaging 28 to 32 percentage points for the background noise, reverberation, and ease of communication subscales. Relative to participants' own hearing aids, the subscales ease of communication and aversiveness showed small but significant improvements for Earlens ranging from 6 to 7 percentage points. For the custom satisfaction questionnaire, most participants rated the Earlens system as better than their own hearing aids in most situations. CONCLUSIONS: Participants used and reported subjective benefit from the Earlens system. Most participants preferred slightly less gain at 6 to 10 kHz than prescribed for experienced users by CAM2, preferring similar gains to those prescribed for inexperienced users, but gains over the extended high frequencies were high relative to those that are currently available with acoustic hearing aids.
引用
- Arbogast TL, Moore BCJ, Puria S, et al. Achieved Gain and Subjective Outcomes for a Wide-Bandwidth Contact Hearing Aid Fitted Using CAM2. Ear Hear. 2019. PMID: 30300158. doi:10.1097/AUD.0000000000000661
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。