动态范围自动增益控制对模拟人工耳蜗聆听中言语掩蔽下句子识别的影响
研究在模拟双侧人工耳蜗处理中比较通道联动与多频带前端自动增益控制(AGC)对言语识别的影响。在信噪比-2 dB下测量双耳句子识别,发现低阈值时通道联动和频带数均有显著主效应,高阈值时通道联动有显著主效应。联动AGC改善更好耳信噪比并保留宽带双耳电平差统计,多频带AGC在非联动时改善双耳电平差统计,结果支持联合使用通道联动与多频带AGC。
要点
- 通道联动AGC在低阈值和高阈值下均显著改善模拟双侧CI的句子识别。
- 多频带AGC在低阈值下显著改善句子识别,且非联动时改善双耳电平差统计。
- 联合多频带与通道联动AGC可兼顾识别增益与动态范围压缩。
核心结论
- 结果支持双侧人工耳蜗采用结合通道联动AGC与多频带AGC的策略。
- 联动AGC有助于空间分离言语下的句子识别,但减小动态范围压缩程度。
- 联合多频带与通道联动AGC可抵消联动AGC动态范围减小的影响而不牺牲识别增益。
研究设计与样本
- 模拟双侧人工耳蜗处理下测量双耳句子识别性能。
- 目标声位于左侧-15或-30°,掩蔽声对称位于右侧,信噪比为-2分贝。
- 分析方差评估通道联动与AGC频带数在两种空间布局及高低AGC阈值下的条件效应。
- 进行声学分析比较处理后更好耳信噪比、双耳间差异及单耳带内包络水平。
主要发现
- 方差分析显示低阈值下通道联动和频带数均有显著主效应,高阈值下通道联动有显著主效应。
- 联动AGC产生更有利的更好耳信噪比并更好保留宽带双耳电平差统计,但动态范围压缩不如非联动AGC。
- 多频带AGC有时改善更好耳信噪比统计,且在AGC通道非联动时总是改善宽带双耳电平差统计。
- 多频带AGC产生的输出包络水平高于单频带AGC。
临床怎么用
- 双侧人工耳蜗前端处理策略可考虑联合采用通道联动与多频带AGC以提升空间分离言语识别。
- 采用联动AGC时需注意其动态范围压缩减少,可通过结合多频带AGC来弥补。
局限性
- 研究为模拟人工耳蜗聆听,非实际植入者测试。
- 仅评估单一目标与单一掩蔽的对称空间布局及-2分贝信噪比条件。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: "Channel-linked" and "multi-band" front-end automatic gain control (AGC) were examined as alternatives to single-band, channel-unlinked AGC in simulated bilateral cochlear implant (CI) processing. In channel-linked AGC, the same gain control signal was applied to the input signals to both of the two CIs ("channels"). In multi-band AGC, gain control acted independently on each of a number of narrow frequency regions per channel. DESIGN: Speech intelligibility performance was measured with a single target (to the left, at -15 or -30°) and a single, symmetrically-opposed masker (to the right) at a signal-to-noise ratio (SNR) of -2 decibels. Binaural sentence intelligibility was measured as a function of whether channel linking was present and of the number of AGC bands. Analysis of variance was performed to assess condition effects on percent correct across the two spatial arrangements, both at a high and a low AGC threshold. Acoustic analysis was conducted to compare postcompressed better-ear SNR, interaural differences, and monaural within-band envelope levels across processing conditions. RESULTS: Analyses of variance indicated significant main effects of both channel linking and number of bands at low threshold, and of channel linking at high threshold. These improvements were accompanied by several acoustic changes. Linked AGC produced a more favorable better-ear SNR and better preserved broadband interaural level difference statistics, but did not reduce dynamic range as much as unlinked AGC. Multi-band AGC sometimes improved better-ear SNR statistics and always improved broadband interaural level difference statistics whenever the AGC channels were unlinked. Multi-band AGC produced output envelope levels that were higher than single-band AGC. CONCLUSIONS: These results favor strategies that incorporate channel-linked AGC and multi-band AGC for bilateral CIs. Linked AGC aids speech intelligibility in spatially separated speech, but reduces the degree to which dynamic range is compressed. Combining multi-band and channel-linked AGC offsets the potential impact of diminished dynamic range with linked AGC without sacrificing the intelligibility gains observed with linked AGC.
引用
- Spencer NJ, Tillery KH, Brown CA, et al. The Effects of Dynamic-range Automatic Gain Control on Sentence Intelligibility With a Speech Masker in Simulated Cochlear Implant Listening. Ear Hear. 2019. PMID: 30204615. doi:10.1097/AUD.0000000000000653