文献速递耳科与耳神经

助听器自验配的「金发姑娘」方法:耳道输出与言语清晰度指数

A "Goldilocks" Approach to Hearing Aid Self-Fitting: Ear-Canal Output and Speech Intelligibility Index.
PubMed 文献 · Ear Hear · 2019-01-01

研究让13名助听器使用者和13名非使用者(轻中度听力损失,组间平均纯音阈值相似)从通用起始条件自调整体音量、高频提升和低频削减,并计算耳道输出与言语清晰度指数(SII)。自调后两组SII均提升至与NAL-NL2处方无显著差异,支持自调基本放大参数可行且有效。

要点

  • 轻中度听力损失者无论有无助听器经验均可完成基本放大参数自调。
  • 自调后SII提升至与NAL-NL2处方无显著差异。
  • 助听器使用者仅在言语测听后显著提高高频输出和SII。

核心结论

  • 用户自调基本放大特性无论有无助听器经验均可行且有效。

研究设计与样本

  • 13名助听器使用者与13名非使用者,组间平均纯音阈值相似,听预先录制并预处理的男声句子。
  • 从通用水平与频谱起始,依次自调整体水平、高频提升和低频削减,并在初步调整后、最终调整前进行言语感知测试。
  • 用自选参数、个体阈值和真耳-耦合器差异计算起始及两次自调条件的输出与SII,并与NAL-NL2处方比较。

主要发现

  • 所有参与者均能完成自调过程。
  • 通用起始条件在2至8 kHz的输出和SII显著低于NAL-NL2处方。
  • 两组自调后SII提升至与处方无显著差异。
  • 助听器使用者在言语感知测试后显著提高高频输出和SII,非使用者无此变化。

关键数值与推荐

  • 13名助听器使用者中8人(62%)现有助听器达到SII 60%标准,最终自调后12人(92%)达标。

临床怎么用

  • 可考虑让轻中度听力损失者自调整体音量、高频提升和低频削减等基本放大参数。
  • 自调可使耳道输出与SII接近NAL-NL2处方水平,有无助听器经验者均可尝试。
  • 言语测听后助听器使用者可能进一步增加高频输出,需关注此反馈效应。

局限性

  • 样本量较小(13名使用者与13名非使用者)。
  • 使用预先录制并预处理的男声句子,非现场言语。
  • 仅评估基本放大参数自调,未涉及其他验配环节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objective was to determine self-adjusted output response and speech intelligibility index (SII) in individuals with mild to moderate hearing loss and to measure the effects of prior hearing aid experience. DESIGN: Thirteen hearing aid users and 13 nonusers, with similar group-mean pure-tone thresholds, listened to prerecorded and preprocessed sentences spoken by a man. Starting with a generic level and spectrum, participants adjusted (1) overall level, (2) high-frequency boost, and (3) low-frequency cut. Participants took a speech perception test after an initial adjustment before making a final adjustment. The three self-selected parameters, along with individual thresholds and real-ear-to-coupler differences, were used to compute output levels and SIIs for the starting and two self-adjusted conditions. The values were compared with an NAL second nonlinear threshold-based prescription (NAL-NL2) and, for the hearing aid users, performance of their existing hearing aids. RESULTS: All participants were able to complete the self-adjustment process. The generic starting condition provided outputs (between 2 and 8 kHz) and SIIs that were significantly below those prescribed by NAL-NL2. Both groups increased SII to values that were not significantly different from prescription. The hearing aid users, but not the nonusers, increased high-frequency output and SII significantly after taking the speech perception test. Seventeen of the 26 participants (65%) met an SII criterion of 60% under the generic starting condition. The proportion increased to 23 out of 26 (88%) after the final self-adjustment. Of the 13 hearing aid users, 8 (62%) met the 60% criterion with their existing hearing aids. With the final self-adjustment, 12 out of 13 (92%) met this criterion. CONCLUSIONS: The findings support the conclusion that user self-adjustment of basic amplification characteristics can be both feasible and effective with or without prior hearing aid experience.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Mackersie C, Boothroyd A, Lithgow A, et al. A "Goldilocks" Approach to Hearing Aid Self-Fitting: Ear-Canal Output and Speech Intelligibility Index. Ear Hear. 2019. PMID: 29894379. doi:10.1097/AUD.0000000000000617

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。