文献速递耳科与耳神经

附加低通滤波语音对噪声带声码语音聆听努力的影响

Effects of Additional Low-Pass-Filtered Speech on Listening Effort for Noise-Band-Vocoded Speech in Quiet and in Noise.
PubMed 文献 · Ear Hear · 2019-01-01

本研究采用双任务范式和NASA任务负荷指数,探讨模拟电声刺激中附加低通滤波语音能否降低噪声带声码语音的聆听努力。结果显示,在安静近天花板识别率下附加低通滤波语音较双耳声码器降低聆听努力;在噪声中,附加低通滤波语音使目标识别率在更差信噪比下达成且未增加聆听努力,50%识别率时甚至进一步降低聆听努力。NASA任务负荷指数未捕捉到这些差异。

要点

  • 附加低通滤波语音在安静近天花板识别率下较双耳声码器降低聆听努力。
  • 在噪声中附加低通滤波语音允许在更差信噪比下达到目标识别率且不增加聆听努力。
  • 50%识别率时附加低通滤波语音在提高噪声容忍度基础上进一步降低聆听努力。

核心结论

  • 双任务结果提供部分证据表明附加低频声学语音可降低噪声带声码语音的聆听努力。

研究设计与样本

  • 采用双任务范式作为行为测量,并以NASA任务负荷指数作为主观自报测量。
  • 主要任务为句子识别,在三个固定识别率水平(近天花板、50%、79%)下进行,通过操纵背景语音形噪声的存在与水平实现。
  • 聆听努力由次要视觉反应时任务的表现反映。
  • 实验语音处理条件包括单耳或双耳声码器,附加或不附加低通滤波语音(模拟电声刺激或人工耳蜗)。

主要发现

  • 实验1中,安静近天花板识别率下,附加低通滤波语音较双耳声码器降低聆听努力,但较单耳声码器未降低。
  • 实验2和3中,噪声下附加低通滤波语音使目标识别率在更差信噪比下达成,且未增加通常与差信噪比相关的聆听努力。
  • 50%识别率时,附加低通滤波语音在提高噪声容忍度基础上进一步降低聆听努力。
  • NASA任务负荷指数未捕捉到上述差异。

临床怎么用

  • 模拟电声刺激中附加低频声学语音可能有助于降低聆听努力,尤其在噪声下。
  • 未来研究需验证这些发现是否适用于有残余听力的耳蜗植入用户。

局限性

  • 有残余听力的耳蜗植入用户可获得的低频声学声音的质量和频率范围可能与理想化模拟不同。
  • 高龄和不同病因等额外因素也可能起作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Residual acoustic hearing in electric-acoustic stimulation (EAS) can benefit cochlear implant (CI) users in increased sound quality, speech intelligibility, and improved tolerance to noise. The goal of this study was to investigate whether the low-pass-filtered acoustic speech in simulated EAS can provide the additional benefit of reducing listening effort for the spectrotemporally degraded signal of noise-band-vocoded speech. DESIGN: Listening effort was investigated using a dual-task paradigm as a behavioral measure, and the NASA Task Load indeX as a subjective self-report measure. The primary task of the dual-task paradigm was identification of sentences presented in three experiments at three fixed intelligibility levels: at near-ceiling, 50%, and 79% intelligibility, achieved by manipulating the presence and level of speech-shaped noise in the background. Listening effort for the primary intelligibility task was reflected in the performance on the secondary, visual response time task. Experimental speech processing conditions included monaural or binaural vocoder, with added low-pass-filtered speech (to simulate EAS) or without (to simulate CI). RESULTS: In Experiment 1, in quiet with intelligibility near-ceiling, additional low-pass-filtered speech reduced listening effort compared with binaural vocoder, in line with our expectations, although not compared with monaural vocoder. In Experiments 2 and 3, for speech in noise, added low-pass-filtered speech allowed the desired intelligibility levels to be reached at less favorable speech-to-noise ratios, as expected. It is interesting that this came without the cost of increased listening effort usually associated with poor speech-to-noise ratios; at 50% intelligibility, even a reduction in listening effort on top of the increased tolerance to noise was observed. The NASA Task Load indeX did not capture these differences. CONCLUSIONS: The dual-task results provide partial evidence for a potential decrease in listening effort as a result of adding low-frequency acoustic speech to noise-band-vocoded speech. Whether these findings translate to CI users with residual acoustic hearing will need to be addressed in future research because the quality and frequency range of low-frequency acoustic sound available to listeners with hearing loss may differ from our idealized simulations, and additional factors, such as advanced age and varying etiology, may also play a role.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Pals C, Sarampalis A, van Dijk M, et al. Effects of Additional Low-Pass-Filtered Speech on Listening Effort for Noise-Band-Vocoded Speech in Quiet and in Noise. Ear Hear. 2019. PMID: 29757801. doi:10.1097/AUD.0000000000000587

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。