文献速递耳科与耳神经

双模式人工耳蜗用户两种助听器验配算法的比较

Comparing Two Hearing Aid Fitting Algorithms for Bimodal Cochlear Implant Users.
PubMed 文献 · Ear Hear · 2019-01-01

结果显示两种公式在2000 Hz及以上频率的增益和1000 Hz及以上频率的压缩比存在显著差异,但双模式听觉表现无差异;双模式刺激在安静和噪声下均带来获益,额外响度平衡对输出影响轻微。

要点

  • APDB公式在2000 Hz及以上提供比NAL-NL2更少的增益。
  • APDB公式在1000 Hz及以上压缩比高于NAL-NL2。
  • 两种公式下双模式听觉表现无差异,NAL-NL2或APDB均可用于双模式验配。

核心结论

  • 对侧有残余听力的CI用户可从双模式刺激中获益,无论采用哪种验配方法。
  • NAL-NL2与APDB公式在输出和压缩比上存在显著差异,但双模式听觉表现无差异。
  • 额外的响度平衡对助听器输出影响轻微。

研究设计与样本

  • 前瞻性交叉设计,比较两种基础处方公式(NAL-NL2或APDB),共三次访视,间隔3周。

主要发现

  • 两种验配公式在2000 Hz及以上频率的增益存在显著差异,APDB提供更少增益。
  • APDB公式在1000 Hz及以上频率的压缩比高于NAL-NL2公式。
  • 响度平衡未导致初始验配公式处方增益的大幅偏离。
  • 在安静和噪声下的言语感知均观察到双模式获益。
  • 两种验配公式在任何听觉表现测试中均未发现差异。

临床怎么用

  • 双模式人工耳蜗用户可受益于双模式刺激,NAL-NL2或APDB处方均可用于验配。
  • 额外响度平衡对助听器输出影响轻微,可根据临床需要决定是否进行。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To investigate the possible advantage of the use of a dedicated bimodal hearing aid fitting formula, the Adaptive Phonak Digital Bimodal (APDB), compared with a frequently used standard hearing aid fitting formula, the NAL-NL2. We evaluated the effects of bimodal hearing aid fitting on provided hearing aid gain and on bimodal auditory functioning in a group of experienced bimodal cochlear implant (CI) users. A second aim of our study was to determine the effect of broadband loudness balancing on the prescribed gain of those two fitting formulas. DESIGN: This prospective study used a crossover design in which two fitting methods were compared varying in basic prescription formula (NAL-NL2 or APDB fitting formula). The study consisted of a three-visit crossover design with 3 weeks between sessions. Nineteen postlingually deafened experienced bimodal CI users participated in this study. Auditory functioning was evaluated by a speech in quiet test, a speech in noise test, and a questionnaire on auditory performance. RESULTS: Significant differences between the two fitting formulas were found for frequencies of 2000 Hz and above. For these frequencies, less gain was provided by the APDB fitting formula compared with NAL-NL2. For the APDB fitting formula, a higher compression ratio for frequencies of 1000 Hz and above was found compared with the NAL-NL2 fitting formula. Loudness balancing did not result in large deviations from the prescribed gain by the initial fitting formula. Bimodal benefit was found for speech perception in quiet and for speech perception in noise. No differences in auditory performance were found between the two fitting formulas for any of the auditory performance tests. CONCLUSIONS: The results of this study show that CI users with residual hearing at the contralateral ear can benefit from bimodal stimulation, regardless of the fitting method that was applied. Although significant differences between the output and compression ratio of the NAL-NL2 and the APDB fitting formula existed, no differences in bimodal auditory performance were observed. Therefore, NAL-NL2 or the APDB fitting prescription both seem suited for bimodal fitting purposes. Additional loudness balancing has a marginal effect on the provided hearing aid output.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Vroegop JL, Homans NC, van der Schroeff MP, et al. Comparing Two Hearing Aid Fitting Algorithms for Bimodal Cochlear Implant Users. Ear Hear. 2019. PMID: 29782445. doi:10.1097/AUD.0000000000000597

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。