文献速递睡眠呼吸障碍小儿耳鼻咽喉

手表式外周动脉张力测定诊断儿童阻塞性睡眠呼吸暂停的准确性研究

Watch Peripheral Arterial Tonometry in the Diagnosis of Pediatric Obstructive Sleep Apnea.
PubMed 文献 · Otolaryngol Head Neck Surg · 2018-04-10

该前瞻性诊断试验纳入36例8至15岁临床疑似OSA儿童,同步进行PSG与手表式PAT监测。结果显示两种方法在AHI(ICC 0.89)和ODI(ICC 0.87)上一致性优良,W-AHI≥10对重度OSA诊断特异性达91.3%,但研究样本量小且缺乏正常对照组。

要点

  • 手表式PAT与PSG在儿童AHI和ODI上一致性优良,ICC分别为0.89和0.87。
  • W-AHI≥10对重度儿童OSA诊断特异性高,达91.3%。
  • 该设备用于儿童OSA诊断仍需更大样本及正常对照组验证。

核心结论

  • 手表式PAT与PSG相关性好且一致性良好,W-AHI≥10对重度儿童OSA诊断特异性高。

研究设计与样本

  • 前瞻性诊断试验研究,纳入36例8至15岁临床疑似OSA儿童,在睡眠实验室同步进行PSG与PAT监测。

主要发现

  • PSG与PAT的AHI中位数分别为8.0(5.5-12)和2.9(0.5-7.5)事件/h。
  • PSG与PAT的ODI中位数分别为2.5(1.4-8.3)和1.3(0.2-3.8)事件/h。
  • PSG与PAT的平均总睡眠时间分别为398.4±38.3和401.9±36.1分钟。
  • PSG与PAT的平均最低血氧饱和度分别为87.1%±8.1%和89.4%±7.1%。
  • AHI的ICC为0.89(95%CI 0.40-0.96,P<.001),ODI的ICC为0.87(95%CI 0.69-0.94,P<.001)。

关键数值与推荐

  • ODI相关性r=0.83(95%CI 0.67-0.90,P<.001),AHI相关性r=0.64(95%CI 0.30-0.85,P<.001)。
  • PAT的W-AHI截断值3.5事件/h诊断准确性最高,灵敏度76.9%、特异度78.3%。
  • W-AHI截断值10事件/h诊断重度OSA的特异度为91.3%。

临床怎么用

  • 手表式PAT可作为儿童OSA的辅助诊断工具,W-AHI≥10时提示重度OSA可能性高。
  • 临床解读儿童PAT结果时需注意其与PSG的AHI绝对数值存在差异。

局限性

  • 样本量仅36例,且未设正常对照组。
  • 研究仅纳入8至15岁儿童,结论外推至其他年龄段需谨慎。
  • 仍需针对各年龄段儿童及正常对照组开展更大规模研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective To assess the accuracy and clinical reliability of watch peripheral arterial tonometry (PAT) compared with polysomnography (PSG) for the diagnosis of pediatric obstructive sleep apnea (OSA). Study Design Prospective, diagnostic test study. Setting National tertiary referral hospital. Subjects and Methods Patients aged 8 to 15 years with clinically suspected OSA were recruited. All participants underwent PSG and PAT simultaneously in the sleep laboratory. Results Thirty-six patients were included, with a mean age of 10.2 ± 1.8 years. Median (interquartile range) of the apnea hypopnea index (AHI) was 8.0 (5.5-12) and 2.9 (0.5-7.5) events/h, median oxygen desaturation index (ODI) was 2.5 (1.4-8.3) and 1.3 (0.2-3.8) events/h, mean ± standard deviation total sleep time was 398.4 ± 38.3 and 401.9 ± 36.1 minutes, and mean minimum oxygen saturation was 87.1% ± 8.1% and 89.4% ± 7.1% for PSG and PAT sleep parameter results, respectively. Agreement between methods was excellent for the AHI (intraclass correlation coefficient [ICC]: 0.89; 95% CI, 0.40-0.96; P < .001) and ODI (ICC: 0.87; 95% CI, 0.69-0.94; P < .001). Correlation between methods was very good for the ODI ( r = 0.83; 95% CI, 0.67-0.90; P < .001) and moderate for the AHI ( r = 0.64; 95% CI, 0.30-0.85; P < .001). From the receiver operating characteristic curve constructed to assess PAT diagnostic capability, AHI of PAT (W-AHI) at a cutoff of 3.5 events/h provided the highest accuracy (76.9% sensitivity, 78.3% specificity), while W-AHI at 10 events/h yielded 91.3% specificity for diagnosing severe OSA. Conclusion PAT correlated well and had good agreement with PSG. Children with W-AHI ≥10 had high specificity for the diagnosis of severe OSA. Larger studies with PAT designed for children across all age ranges and with a normal control group are still needed.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Tanphaichitr A, Thianboonsong A, Banhiran W, et al. Watch Peripheral Arterial Tonometry in the Diagnosis of Pediatric Obstructive Sleep Apnea. Otolaryngol Head Neck Surg. 2018. PMID: 29631515. doi:10.1177/0194599818768215

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。